نتایج جستجو برای: water phantom

تعداد نتایج: 566361  

2016
Ambreen Aslam Muhammad Basim Kakakhel Shaukat Ali Shahid Lubna Younas Sobia Zareen

In this work, soft-tissue equivalence of water, polystyrene, PMMA and water equivalence of polystyrene, and PMMA has been assessed for multiple megavoltage photon beams and field sizes. EGSnrc based Monte Carlo (MC) codes, BEAMnrc and DOSXYZnrc are used for the linac head modeling and the phantom dose calculations, respectively. Percentage depth doses (PDDs) are scored for two field sizes (5 × ...

Introduction: The performance of computed tomography is routinely checked using phantoms, which are known as important diagnostic imaging tools. Depending upon the aim of the study, different phantoms are designed, while trying to satisfy certain levels of diversities in their application. Material and Methods: The present study describes the...

Introduction: The present study aimed to generate intensity-modulated beams with Aluminium compensating filters for a conventional telecobalt machine based on the outputs of a treatment planning system (TPS) performing forward planning and cannot simulate directly the compensating filter. Materials and Methods: In order to achieve the beam intensity modulation during treatment planning with th...

احمدی, ام لیلا, توکلی عنبران, حسین,

Introduction: The dosimetry of the brachytherapy sources is performed in the water source medium according to protocol TG-43U1. To achieve a resonable results on treatment, the use of the water material for all body tissues can be one of the faulty sources in delivering the correct dose to the tumor. Thus, we have focused on the dosimetry parameters in fat density 0.95 gr/cm3 and the muscle wit...

Journal: :iranian journal of radiation research 0
m.j. tahmasebi birgani medical physics department, jondi shapour university of medical sciences, ahwaz, iran m.a. behrooz medical physics department, jondi shapour university of medical sciences, ahwaz, iran h. shahbazian radiation therapy department, golestan hospital, jondi shapour university of medical science, ahwaz, iran a. shams medical physics department, jondi shapour university of medical sciences, ahwaz, iran

background: attenuation coefficient (μ) plays an important role in calculations of treatment planning systems, as well as determination of dose distributions in external beam therapy, dosimetry, protection, phantom materials and industry. so, its exact measurement or calculation is very important. the aim of this study was to evaluate the μ in different points in the water phantom analytically ...

2015
Sune H. Keller Björn Jakoby Susanne Svalling Andreas Kjaer Liselotte Højgaard Thomas L. Klausen

BACKGROUND We present a quick and easy method to perform quantitatively accurate PET scans of typical water-filled PET plastic shell phantoms on the Siemens Biograph mMR PET/MR system. We perform regular cross-calibrations (Xcal) of our PET systems, including the PET/MR, using a Siemens mCT water phantom. LONG-TERM STABILITY The mMR calibration stability was evaluated over a 3-year period whe...

Journal: :Medical physics 2013
Yu Kuang Guillem Pratx Magdalena Bazalova Jianguo Qian Bowen Meng Lei Xing

PURPOSE Developing an imaging method to directly monitor the spatial distribution of platinum-based (Pt) drugs at the tumor region is of critical importance for early assessment of treatment efficacy and personalized treatment. In this study, the authors investigated the feasibility of imaging platinum (Pt)-based drug distribution using x-ray fluorescence (XRF, a.k.a. characteristic x ray) CT (...

Journal: :NMR in biomedicine 2013
E Vescovo A Levick C Childs G Machin S Zhao S R Williams

Currently, there is very limited ability to measure the temperature of the brain, but a direct technique for its estimation in vivo could improve the detection of patients at risk of temperature-related brain damage, help in the diagnosis of stroke and tumour, and provide useful information on the mechanisms of thermoregulation of the brain. In this article, new calibrations in vitro of MRS the...

2013
Yasuyuki Takahashi Masao Miyagawa Yoshiko Nishiyama Hayato Ishimura Teruhito Mochizuki

OBJECTIVE The performance of a new single photon emission computed tomography (SPECT) scanner with a cadmium-zinc-telluride (CZT) solid-state semiconductor detector (Discovery NM 530c; D530c) was evaluated and compared to a conventional Anger-type SPECT with a dual-detector camera (Infinia). METHODS Three different phantom studies were performed. Full width at half maximum (FWHM) was measured...

2016
H. Dadgar

Background: Accurate dose calcula ons in small beamlets and lung material have been a great challenge for most of treatment planning systems (TPS). In the current study, the dose calcula on accuracy of TiGRT TPS was evaluated for small beamlets in water and lung phantom by comparison to Monte Carlo (MC) calcula ons. Materials and Methods: The head of Siemens Oncorimpression linac was simulated ...

نمودار تعداد نتایج جستجو در هر سال