نتایج جستجو برای: آلیاژ حافظهدار niti

تعداد نتایج: 5081  

2016
Leandro de Arruda Santos Pedro Damas Resende Maria Guiomar de Azevedo Bahia Vicente Tadeu Lopes Buono

The effects of the presence of the R-phase in a near-equiatomic NiTi alloy on the mechanical responses of an endodontic instrument were studied by using finite element analysis. The input data for the constitutive model in the simulation were obtained by tensile testing of three NiTi wires: superelastic austenite NiTi, austenite + R-phase NiTi, and fully R-phased NiTi. The wires were also chara...

2014
Tatiana Sobottka SPINI Fabrício Pinelli VALARELLI Rodrigo Hermont CANÇADO Karina Maria Salvatore de FREITAS Denis Jardim VILLARINHO

OBJECTIVES The shape memory resulting from the superelasticity and thermoelastic effect is the main characteristic of thermally activated NiTi archwires and is closely related to the transition temperature range (TTR). The aim of this study was to evaluate the TTR of thermally activated NiTi archwires commercially available. MATERIAL AND METHODS Seven different brands of 0.019" x 0.025" therm...

2013
C C Tsao J U Liou P H Wen C C Peng T S Liu

AIM To develop analytical models and analyse the stress distribution and flexibility of nickel-titanium (NiTi) instruments subject to bending forces. METHODOLOGY The analytical method was used to analyse the behaviours of NiTi instruments under bending forces. Two NiTi instruments (RaCe and Mani NRT) with different cross-sections and geometries were considered. Analytical results were derived...

2007
Qiang Pan Chongdu Cho

Some shape memory alloys like NiTi show noticeable high damping property inpseudoelastic range. Due to its unique characteristics, a NiTi alloy is commonly used forpassive damping applications, in which the energy may be dissipated by the conversion frommechanical to thermal energy. This study presents a shape memory alloy based micro-damper, which exploits the pseudoelasticity of NiTi wires fo...

2011
Rogério Lacerda dos Santos Matheus Melo Pithon Leonard Euler A. G. Nascimento Fernanda Otaviano Martins Maria Teresa Villela Romanos Matilde da Cunha G. Nojima Lincoln Issamu Nojima

Objective: The welding process involves metal ions capable of causing cell lysis. In view of this fact, the aim of this study was to test the hypothesis that cytotoxicity is present in different types of alloys (CrNi, TMA, NiTi) commonly used in orthodontic practice when these alloys are subjected to electric spot welding. Methods: Three types of alloys were evaluated in this study. Thirty-six ...

Journal: :Acta biomaterialia 2008
A Bansiddhi T D Sargeant S I Stupp D C Dunand

NiTi foams are unique among biocompatible porous metals because of their high recovery strain (due to the shape-memory or superelastic effects) and their low stiffness facilitating integration with bone structures. To optimize NiTi foams for bone implant applications, two key areas are under active study: synthesis of foams with optimal architectures, microstructure and mechanical properties; a...

2009
Aleksandra Jeličić Alwin Friedrich Katarina Jeremić Gerd Siekmeyer Andreas Taubert

One of the main issues with the use of nickel titanium alloy (NiTi) implants in cardiovascular implants (stents) is that these devices must be of very high quality in order to avoid subsequent operations due to failing stents. For small stents with diameters below ca. 2 mm, however, stent characterization is not straightforward. One of the main problems is that there are virtually no methods to...

2015
Abdul Razzak A. Ghazal Mohammad Y. Hajeer Rabab Al-Sabbagh Ibrahim Alghoraibi Ahmad Aldiry

BACKGROUND This study aimed to compare superelastic and heat-activated nickel-titanium orthodontic wires' surface morphology and potential release of nickel ions following exposure to oral environment conditions. METHODS Twenty-four 20-mm-length distal cuts of superelastic (NiTi Force I®) and 24 20-mm-length distal cuts of heat-activated (Therma-Ti Lite®) nickel-titanium wires (American Ortho...

2012
WooCheol Lee Minju Song Euiseong Kim Hyojin Lee Hyeon-Cheol Kim

OBJECTIVES The purpose was to investigate the preference and usage technique of NiTi rotary instruments and to retrieve data on the frequency of re-use and the estimated incidence of file separation in the clinical practice among general dentists. MATERIALS AND METHODS A survey was disseminated via e-mail and on-site to 673 general dentists. The correlation between the operator's experience o...

2015
Seok-Woo Chang

In the clinical practice, it is much more efficient to use NiTi rotary files compared to hand instrumentation. However, misuse of NiTi rotary files can result in procedural errors such as transportation, ledge, perforation, and file separation. Generally, following suggestions could be considered to avoid these errors. 1. Enlarge the coronal half of the root canal before preparing the apical pa...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید