نتایج جستجو برای: acrylic abutments

تعداد نتایج: 10429  

Journal: :Clinical oral implants research 2009
Irena Sailer Alexander Philipp Anja Zembic Bjarni E Pjetursson Christoph H F Hämmerle Marcel Zwahlen

OBJECTIVES The objective of this systematic review was to assess the 5-year survival rates and incidences of complications associated with ceramic abutments and to compare them with those of metal abutments. METHODS An electronic Medline search complemented by manual searching was conducted to identify randomized-controlled clinical trials, and prospective and retrospective studies providing ...

Journal: :The International journal of prosthodontics 2017
Manami Abe Tsung-Chieh Yang Yoshionobu Maeda Takanori Ando Masahiro Wada

PURPOSE The purpose of this preliminary in vivo study was to compare force distribution on abutments (tooth or implant) and tissues supporting overdentures with two or four abutments. MATERIALS AND METHODS A convenience sample of five subjects with tooth and/or implant-supported overdentures was enrolled. Recordings were completed on each subject using a force-measuring system mounted on a me...

Journal: :Clinical oral implants research 2008
Maria Welander Ingemar Abrahamsson Tord Berglundh

OBJECTIVE The aim of the present study was to analyze the soft tissue barrier formed to implant abutments made of different materials. MATERIAL AND METHODS Six Labrador dogs, about 1 year old, were used. All mandibular premolars and the first, second and third maxillary premolars were extracted. Three months later four implants (OsseoSpeed, 4.5 x 9 mm, Astra Tech Dental, Mölndal, Sweden) were...

Journal: :Journal of oral rehabilitation 2005
F Butz G Heydecke M Okutan J R Strub

The aim of this study was to compare titanium-reinforced ZrO(2) and pure Al(2)O(3) abutments regarding their outcome after chewing simulation and static loading. Forty-eight standard diameter implants with an external hexagon were divided into three groups of 16 implants each and restored with three different types of abutments (group A: ZrO(2) abutments with titanium inserts; group B: Al(2)O(3...

Journal: :The International journal of oral & maxillofacial implants 1998
G Faulkner J Wolfaardt V del Valle

Retention of implant-supported facial prostheses presents challenges in design that may lead to use of freestanding abutments. This is particularly so in the midface and orbit. Individual implant success rates are lower in these regions, and bone remodeling capacity may be compromised by combined modality cancer therapy. The present study was undertaken to determine the variations in load deliv...

Journal: :The journal of contemporary dental practice 2013
Rodrigo Antonio de Medeiros Aljomar José Vechiato-Filho Eduardo Piza Pellizzer Jose Vitor Quinelli Mazaro Daniela Micheline dos Santos Marcelo Coelho Goiato

AIM The aim of this study is to evaluate through a literature review, the soft tissue response in contact with zirconia abutments, including case reports comparing prosthetics rehabilitations with zirconia and titanium abutments upto 3 years of follow-up as well as the factors that should be considered on implant's abutment selection. BACKGROUND Metallic abutments can provide grayish color wh...

Journal: :Journal of clinical and diagnostic research : JCDR 2014
Nabaprakash Sahu Namratha Lakshmi N S Azhagarasan Yoshaskam Agnihotri Manoj Rajan Ramasubramanian Hariharan

BACKGROUND In cement-retained implant-supported restoration it is important to gain adequate retention of definitive restoration as well as retrievability of prosthesis. The surface of the abutment, alloy of the restoration and the type of cement used influences the retention of the restoration. There is a need to analyze the influence of surface modifications of abutments on the retentive capa...

ژورنال: مجله دندانپزشکی 2012
امتی شبستری, قاسم, شعبانپور, رضا, علی‌خاصی, مرضیه, منزوی, عباس,

Background and Aims: One of the decisive factors on the final esthetic results of implant treatment is the abutment material. Ceramic abutments are nowadays very popular in this regard. The purpose of this study was to compare the fracture resistance of three zirconia abutments with titanium abutment. Materials and Methods: Four groups of abutments (five specimens in each) were prepared. The a...

Journal: :The Journal of prosthetic dentistry 2017
Adham Elsayed Sebastian Wille Majed Al-Akhali Matthias Kern

STATEMENT OF PROBLEM The whitish color of zirconia (ZrO2) abutments offers favorable esthetics compared with the grayish color of titanium (Ti) abutments. Nonetheless, ZrO2 has greater opacity, making it difficult to achieve natural tooth color. Therefore, lithium disilicate (LaT) abutments have been suggested to replace metal abutments. PURPOSE The purpose of this in vitro study was to evalu...

2017
Anita Kapri Arun Gupta Sudhir Joshi

Dental implants have been a universally accepted option for prosthetic rehabilitation of partially edentulous patients. Titanium implants abutments exhibit a dull grayish hue and give an unnatural appearance. Abutments based on zirconia are one of the alternatives to titanium abutments. To date, few comparative studies have reported on esthetic and biological outcomes of implant-supported resto...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید