نتایج جستجو برای: air conditioners

تعداد نتایج: 206149  

2006
BEI WU YAN ZHANG MINJIANG CHEN

Based on reactive power-voltage characteristics analysis of air conditioners, the effects of air conditioner load on voltage stability of an urban power system are investigated in this paper. Indexes for evaluating bus voltage security are proposed, and static voltage stability analysis method is adopted. The computational analysis of a real urban power system in East China shows that air condi...

1998
I. L. Maclaine-cross E. Leonardi

Measurements on R600a refrigerators have shown electricity savings over R134a and R12 up to 20%. We propose new parameters which are functions of well known refrigerant properties. These parameters show that R600a has half the leakage, pressure loss and condenser pressure and double the heat transfer coefficient of R12 and R134a explaining the measurements. Use of R600a in small heat pumps and ...

2013
Richa Soni

This review paper presents the work of various researches on the performance of capillary tube ,used in air conditioners with various refrigerants. Research carried out by different authors uses different type of capillary tubes (straight, twisted, coiled) in different length and diameter. they determined various parameters like coefficient of performance (COP),cooling capacity, energy efficien...

2015
Maximilian Auffhammer

The widespread rollout of air conditioning has resulted in massive positive impacts on human health in both developing and developed countries over the past century. A warming world will further increase demand for cooling in climates both through increased operation of existing air conditioners and the adoption of new ones. This paper provides an empirical approach to separately quantifying th...

Journal: :Intelligent Automation & Soft Computing 2012
Haiyan Zhu Wenqin Cao Jinliang Nie

This paper presents the detailed design and analysis of an asymmetric fin tube condenser. And the heat transfer performance of the asymmetric fin tube condenser is simulated with the fluent software. Based on the simulation results, an optimal model of the asymmetric-finned tube condenser is designed. The actual model is experimentally studied on air conditioners and contrasted with the symmetr...

2002
Jeffrey Siegel

Residential air conditioning is responsible for a substantial amount of peak electrical demand and energy consumption throughout most of the United States. Coil fouling, the deposition of indoor dusts and other particulate matter on evaporator heat exchangers, increases system pressure drop and, correspondingly, decreases system air flow and air conditioner performance. In this paper, we apply ...

2014
M. W. Spatz J. Zheng Mark W. Spatz Jing Zheng

In this paper the results of both modeling and testing a representative 3-ton air-to-air heat pump running with the baseline refrigerant (HCFC-22) and zero ODP alternative refrigerants will be presented. Alternative refrigerant simulation runs are made with two pure fluids (HFC-134a and HFC-152a) and an azeotropicmixture (60/40wt%) ofHFC-32 and HFC125 (Allied-Signal Inc. U.S. Patent 4,978,467)....

2014
B. Chen J. E. Braun Bin Chen James E. Braun Ray W Herrick

2012
Michael P. Summers Rex D. Simmons George Verikios

Despite the known difficulties many people with MS have with high ambient temperatures, there are no reported studies of air conditioning use and MS. This study systematically examined air conditioner use by Australians with MS. A short survey was sent to all participants in the Australian MS Longitudinal Study cohort with a response rate of 76% (n = 2,385). Questions included hours of air-cond...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید