نتایج جستجو برای: annular frictional pressure

تعداد نتایج: 422914  

Journal: :health scope 0
amirabbas mofidi department of occupational health engineering, faculty of medical sciences, tarbiat modares university, tehran, ir iran hassan asilian department of occupational health engineering, faculty of medical sciences, tarbiat modares university, tehran, ir iran; department of occupational health engineering, faculty of medical sciences, tarbiat modares university, tehran, ir iran. tel.: +98-9123873932, fax: +98-2182883825 ahmad jonidi jafari department of environment health engineering, faculty of medical sciences, tarbiat modares university, tehran, ir iran

conclusions results indicated that annular fluidized bed reactor’s adsorbers are useful techniques for vocs adsorption. comparison of two particle ranges indicates that in all concentrations and all flow rates of the experiments, smaller particle size adsorption are better. in superficial velocity above the minimum fluidization velocity, pressure drop of fluidized beds are less than the pressur...

2002
Masayuki Fujita Benjamin F. Chao Braulio V. Sanchez Thomas J. Johnson

[1] We calculate that the oceanic torque vectors (x, y, z components) acting on the solid Earth using the Parallel Ocean Climate Model (POCM) output data at 3-day intervals for the period 1988–1995. This study examined three distinct types of torque, with different physical mechanisms: pressure, gravitational, and frictional. The pressure torque is further divided into two parts: that due to Ea...

2012
Melissa M. Levack Arminder S. Jassar Eric K. Shang Benjamin M. Jackson Joseph H. Gorman

Background—Proponents of flexible annuloplasty rings have hypothesized that such devices maintain annular dynamics. This hypothesis is based on the supposition that annular motion is relatively normal in patients undergoing mitral valve repair. We hypothesized that mitral annular dynamics are impaired in ischemic mitral regurgitation and myxomatous mitral regurgitation. Methods and Results—A Ph...

Journal: :Physical review. E, Statistical, nonlinear, and soft matter physics 2007
Kostya Shundyak Martin van Hecke Wim van Saarloos

We show that in slowly generated two-dimensional packings of frictional spheres, a significant fraction of the friction forces lie at the Coulomb threshold-for small pressure p and friction coefficient mu , about half of the contacts. Interpreting these contacts as constrained leads to a generalized concept of isostaticity, which relates the maximal fraction of fully mobilized contacts and cont...

Journal: :The Journal of the Acoustical Society of America 2003
Paul D Fox Jiqi Cheng Jian-yu Luc

A one-dimensional (1D) Fourier-Bessel series method for computing and tuning (beamforming) the linear lossless field of flat pulsed wave annular arrays is developed and supported with both numerical simulation and experimental verification. The technique represents a new method for modeling and tuning the propagated field by linking the quantized surface pressure profile to a known set of limit...

2007
G. Ooms C. Vuik P. Poesio

A theoretical investigation has been made of core-annular flow: the flow of a high-viscosity liquid core surrounded by a low-viscosity liquid annular layer through a horizontal pipe. Special attention is paid to the question of how the buoyancy force on the core, caused by a density difference between the core and the annular layer, is counterbalanced. From earlier studies it is known that at t...

Journal: :Circulation 2012
Melissa M Levack Arminder S Jassar Eric K Shang Mathieu Vergnat Y Joseph Woo Michael A Acker Benjamin M Jackson Joseph H Gorman Robert C Gorman

BACKGROUND Proponents of flexible annuloplasty rings have hypothesized that such devices maintain annular dynamics. This hypothesis is based on the supposition that annular motion is relatively normal in patients undergoing mitral valve repair. We hypothesized that mitral annular dynamics are impaired in ischemic mitral regurgitation and myxomatous mitral regurgitation. METHODS AND RESULTS A ...

Journal: :European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery 2009
Mathieu Vergnat Roland Henaine Martins Kalejs Sandra Bommeli Enrico Ferrari Jean-Francois Obadia Ludwig Karl Von Segesser

OBJECTIVE Balloon-expandable stent valves require flow reduction during implantation (rapid pacing). The present study was designed to compare a self-expanding stent valve with annular fixation versus a balloon-expandable stent valve. METHODS Implantation of a new self-expanding stent valve with annular fixation (Symetis, Lausanne, Switzerland) was assessed versus balloon-expandable stent val...

2005
M. Ciavarella

In this note, we determine the stability boundary for the thermoelastic contact of a rectangular elastic block sliding against a rigid wall in the presence of a pressure-dependent thermal contact resistance. This geometry can be seen as intermediate between the idealized ‘Aldo’ rod model and continuum solutions for the elastic half-plane. The solution is obtained by comparing the expression for...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید