نتایج جستجو برای: attenuation emission data

تعداد نتایج: 2593617  

Journal: :Physics in medicine and biology 2010
Andrew Thomas James Bowsher Justin Roper Tim Oliver Mark Dewhirst Mark Oldham

Optical-computed tomography (CT) and optical-emission computed tomography (ECT) are recent techniques with potential for high-resolution multi-faceted 3D imaging of the structure and function in unsectioned tissue samples up to 1-4 cc. Quantitative imaging of 3D fluorophore distribution (e.g. GFP) using optical-ECT is challenging due to attenuation present within the sample. Uncorrected reconst...

Journal: :Physics in medicine and biology 1994
Z Liang J Ye D P Harrington

An analytical approach to quantitative brain SPECT (single-photon-emission computed tomography) with non-uniform attenuation is developed. The approach formulates accurately the projection-transform equation as a summation of primary- and scatter-photon contributions. The scatter contribution can be estimated using the multiple-energy-window samples and removed from the primary-energy-window da...

Journal: :NeuroImage 2005
Marie-Louise Montandon Habib Zaidi

Photon attenuation in tissues is the primary physical degrading factor limiting both visual qualitative interpretation and quantitative analysis capabilities of reconstructed Positron Emission Tomography (PET) images. This study investigates the implementation and applicability of transmission atlas-guided attenuation correction in cerebral 3D PET imaging, thus eliminating the need for acquisit...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2007
K Lance Gould Tinsu Pan Catalin Loghin Nils P Johnson Ashrith Guha Stefano Sdringola

UNLABELLED Cardiac PET combined with CT is rapidly expanding despite artifactual defects and false-positive results due to misregistration of PET and CT attenuation correction data-the frequency, cause, and correction of which remain undetermined. METHODS Two hundred fifty-nine consecutive patients underwent diagnostic rest-dipyridamole myocardial perfusion PET/CT using (82)Rb, a 16-slice PET...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2007
Adam M Alessio Steve Kohlmyer Kelley Branch Grace Chen James Caldwell Paul Kinahan

UNLABELLED In dual-modality PET/CT systems, the CT scan provides the attenuation map for PET attenuation correction. The current clinical practice of obtaining a single helical CT scan provides only a snapshot of the respiratory cycle, whereas PET occurs over multiple respiratory cycles. Misalignment of the attenuation map and emission image because of respiratory motion causes errors in the at...

2011
J. M. Warwick S. Rubow M. du Toit E. Beetge P. Carey P. Dupont

Purpose. Striatal single photon emission computed tomography (SPECT) imaging of the dopaminergic system is becoming increasingly used for clinical and research studies. The question about the value of nonuniform attenuation correction has become more relevant with the increasing availability of hybrid SPECT-CT scanners. In this study, the value of nonuniform attenuation correction and correctio...

Journal: :Annals of nuclear medicine 2001
Y Ohyama S Tomiguchi T Kira M Kira A Tsuji A Koi M Matsumoto M Takahashi Y Inobe H Yasue

PURPOSE This study evaluates not only the clinical usefulness but also the problems in attenuation correction for thallium-201 (Tl-201) myocardial SPECT by means of simultaneous transmission and emission data acquisition in the detection of coronary artery disease (CAD). METHODS A three-detector SPECT system equipped with a Tc-99m line source and fan-beam collimators was used for simultaneous...

Journal: :Physics in medicine and biology 1994
J Ye Z Liang D P Harrington

An efficient reconstruction method for myocardial perfusion single-photon emission computed tomography (SPECT) has been developed which compensates simultaneously for attenuation, scatter, and resolution variation. The scattered photons in the primary-energy-window measurements are approximately removed by subtracting the weighted scatter-energy-window samples. The resolution variation is corre...

1999
J. J. Kurland D. A. Morgott R. W. Hamilton

................................................................................................................................... 1 VOLATILIZATION ....................................................................................................................... 2 FATE ANALYSIS ...................................................................................................................

2009
KI YU Siu Ki Yu C. Nahmias

Accurate attenuation correction is a prerequisite for the determination of precise regional radioactivity concentrations in positron tomography. Attenuation correction can be performed using an external source of radiation and two measurements: a blank scan performed with no subject in the tomograph, and a transmission scan performed with the subject in the field of view. The ratio of blank to ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید