نتایج جستجو برای: cannula

تعداد نتایج: 5635  

2015
Martin Gothner Dirk Buchwald Justus T Strauch Thomas A Schildhauer Justyna Swol

BACKGROUND The use of a double lumen cannula for veno-venous extracorporeal membrane oxygenation (v.v. ECMO) offers several advantages such as cannulation with only one cannula, patient comfort and the earlier mobilization and physiotherapy. The cannulation should be performed under visual wire and cannula placement into the right atrium, which is associated with risks of malposition and right ...

Journal: :iranian journal of pharmaceutical research 0
parichehr yaghmaei department of animal biology, science and research branch, islamic azad university, tehran, iran. shahrbanoo oryan department of biology karaj branch, islamic azad university, karaj, iran. khadijeh mohammadi department of animal biology, science and research branch, islamic azad university, tehran, iran. jalal solati department of biology, karaj branch, islamic azad university, karaj, iran.

in the present study, we have investigated the effects of silymarine on depression and the possible role of serotonergic system in these effects. the rats were anesthetized intraperitoneally with ketamine hydrochloride and placed in a stoelting stereotaxic instrument. a stainless steel guide cannula (22-gauge) was implanted in the third ventricular region. the third ventricular region was infus...

Journal: :The journal of extra-corporeal technology 2002
Keri Humphries Joseph J Sistino

Vacuum-assisted venous drainage (VAVD) is frequently used to increase venous return through smaller venous cannula and reduced venous line size. The purpose of this study is to determine the maximal flow rates achieved through various venous cannula with varying amounts of negative pressure applied during VAVD. The first test circuit consisted of 25 different venous cannulae connected to 3/8 in...

Journal: :The British journal of ophthalmology 1978
A J Lyne

A double cannula is described suitable for the aspiration of soft lens matter. The cannula is a modification of a double irrigation needle already marketed and will be available in a presterilised disposable pack for use with disposable syringes.

2017
Hong-Zhuan Song Juan-Xian Gu Hui-Qing Xiu Wei Cui Gen-Sheng Zhang

OBJECTIVE To investigate the value of high-flow nasal cannula oxygen therapy after extubation in patients with acute respiratory failure. METHODS A single-center, prospective, randomized, controlled pilot trial was conducted between January 2013 and December 2014. Sixty enrolled patients were randomized immediately after extubation into either a high-flow nasal cannula group (n=30) or an air ...

Journal: :The journal of extra-corporeal technology 2012
Michael Poullis

Aortic root and valve clots are rare but well described in patients on maximal left ventricular assist device (LVAD) support. We performed a theoretical analysis using computational fluid dynamic analyses in two dimensions to try and ascertain if inflow cannula design/orientation/placement affect aortic root flow dynamics. Two-dimensional computational fluid dynamics using easy CFD-G was perfor...

2016
Chelsea Snider Ashley Amalfi Lauren Hutchinson Nicole Sommer

Methods: Fat is harvested using disposable Caraway harvest cannula; processed with a bi-laminar filtration system and injected with disposable 18 gauge cannula. Intravenous clindamycin is given 1 hour before surgery and the intraoral mucosa at the site of injection is re-prepped with betadine. The upper lip is retracted and approximately 1–1.5 cm above and medial to the Stensen’s duct, the inje...

Journal: :Paediatric anaesthesia 2010
Karina Johansen Rolf J Holm-Knudsen Birgitte Charabi Michael S Kristensen Lars Simon Rasmussen

BACKGROUND An unanticipated difficult airway is very uncommon in infants. The recommendations for managing the cannot ventilate-cannot intubate (CVCI) situation in infants and small children are based on difficult airway algorithms for adults. These algorithms usually recommend placement of a transtracheal cannula or performing a surgical tracheotomy as a last resort. In this study, we compared...

2017
Monish S Raut Arun Maheshwari Sumir Dubey Ganesh Shivnani Sandeep Joshi Arvind Verma Swetanka Das

Malposition of venous cannula can cause inadequate venous drainage during cardiopulmonary bypass. It would be good clinical practice to use TEE to check the position of inferior venous cannula to avoid this problem at the earliest.

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید