نتایج جستجو برای: carbon ceramic electrode
تعداد نتایج: 358288 فیلتر نتایج به سال:
a thin film of epinephrine (ep) was electrochemically deposited on the surface of glassy carbon electrode previously activated in nahco3 solution. the cyclic voltammograms of the modified electrode indicate that the surface confined ep are strongly dependent on the solution ph, as expected for quinone/hydroquinone functionalities. the ep-modified glassy carbon electrode exhibited catalytic acti...
The electrochemical oxidation of repaglinide has been carried out in Britton-Robinson buffer at carbon paste and glassy carbon electrodes. Repaglinide exhibits a well-defined irreversible oxidation peak over the entire pH range (2-11). Differential pulse voltammetry was used to determine repaglinide in pure form. The peak current varied linearly in the following ranges: 8.0 x 10(-7)-3.2 x 10(-6...
a graphene nanosheets (gns) film coated glassy carbon electrode (gce) was fabricated for sensitive determination of tyrosine (tyr). the gns-based sensor was characterized by scanning electron microscope and electrochemical impedance spectroscopy. the voltammetric techniques were employed to study electro-oxidation of tyr. the results revealed that the modified electrode showed an electrocatalyt...
The present paper describes the characterization of a carbon ceramic electrode modified with ferrocenecarboxylic acid (designated as CCE/Fc) by electrochemical techniques and its detection ability for dopamine. From cyclic voltammetric experiments, it was observed that the CCE/Fc presented a redox pair at E(pa) = 405 mV and E(pc) = 335 mV (ΔE = 70 mV), related to the ferrocene/ferrocenium proce...
the electrochemical behavior of a modified carbon paste electrode (mcpe) with n,n′ethylenbis(salicylideneiminato)copper(ii) complex ([cu(ii)-salen]) was investigated as a newsensor for cystein. the britton-robinson buffer with ph 5, 10% modifier in electrode, potentialscanning rate of 20 mvs-1 and puls height of 50 mv were used as the optimum condition for thedetermination of cysteine using car...
A novel chemically modified electrode was constructed based on multi-walled carbon nanotubes, MCM48 molecular sieve composite modified glassy carbon electrode .The modified electrode showed that it can be used for simultaneous determination of acetaminophen (ACT) and codeine (COD), simultaneously. The measurements were carried out by the application of differential pulse voltammetry (DPV), cycl...
Electrochemical behaviour of acetaminophen at the multi wall carbon nanotubes/titanium dioxide (MWCNT/TiO2) composite film modified glassy carbon electrode (GCE) via solvent casting method was studied. It is shown that the MWCNT/TiO2/GCE exhibits remarkable improvement in analytical response as compared to other electrodes. Comparing the responses of the MWCNT/TiO2/GCE with that obtained at the...
This paper describes the development, electrochemical characterization and utilization of novel modified molybdenum (VI) complex-carbon nanotube paste electrode for the electrocatalytic determination of ascorbic acid (AA). The electrochemical profile of the proposed modified electrode was analyzed by cyclic voltammetry (CV) that showed a shift of the oxidation peak potential of AA about 235 mV ...
a chemically modified carbon paste electrode with multiwall carbon nanotube (mwcnt) was prepared and used as a sensor for cu2+ ion. the unique chemical and physical properties of cnt have paved the way to new and improved sensing devices. a central composite chemometrics design was applied for multivariate optimization of the effects of three significant parameters (graphi...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید