نتایج جستجو برای: collimator angle

تعداد نتایج: 133117  

Journal: :Physical review 2023

Inverse Compton scattering of polarized laser photons by energetic electrons is an excellent method to generate gamma rays. A 100% can rays, but polarization varies depending on the angle In this study, we experimentally measure spatial distribution circularly rays using a magnetized iron that circular MeV Measurements asymmetry gamma-ray transmission relative at each clearly show are near cent...

2010
Tarek Halabi Bruce Faddegon

We design a practical procedure for measuring translational and rotational misalignment of graticule with collimator axis of rotation and collimator jaws, respectively. The procedure's quantitative results are accurate to less than 0.2 mm (at isocenter) and do not assume alignment of radiation focal spot with collimator axis of rotation. When provided with these quantitative results, the manufa...

2014
Tomoe Fukamachi Sukswat Jongsukswat Dongying Ju Riichirou Negishi Keiichi Hirano Takaaki Kawamura

Some characteristics are reported of a triple-crystal diffractometer with a (+, -, +) setting of Si(220) using mirage diffraction. The first crystal is flat, while the second and third crystals are bent. Basically, the first crystal is used as a collimator, the second as a monochromator and the third as the sample. The third crystal also works as an analyzer. The advantages of this diffractomet...

Journal: :Review of Scientific Instruments 2021

This article provides information about the sizing and standardization of a Faraday cup (FC) used as plasma diagnostic. instrument is to accurately map ion beam profile produced by an electric propulsion (EP) device. A FC cylindrical probe that uses electrode, termed collector, measure current. Several studies have shown relevance adding extra called collimator, define collection area minimize ...

2014
Hendrik O. Colijn Fan Yang D. B. Williams Alan Sandborg David W. McComb

External SDD systems can also replace Si(Li) detectors on existing microscopes and offer many of the advantages of the in-situ SDD systems. Since the SDDs do not operate at liquid nitrogen temperatures, the insulation gaps in the nosepiece/collimator assemblies can be reduced or eliminated. Also, the detector window and the associated support frame are no longer used. This means that the detect...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 1988
R J Jaszczak K L Greer R E Coleman

A specially designed high resolution converging collimator having a focal length of 50 cm has been evaluated for cone beam single photon emission computed tomography (SPECT). The focal region was investigated by imaging a point source placed at the expected focal point and along the central ray of the collimator in front of and behind the focal point. Technetium-99m point source sensitivities m...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 1986
B M Tsui G T Gullberg E R Edgerton D R Gilland J R Perry W H McCartney

A long bore fan beam collimator for imaging the head was designed and constructed for a SPECT system with a rotating scintillation camera. In order to avoid the patient's shoulder during rotation of the camera with a thick camera housing, the long bore design is necessary to allow the collimator to get close to the patient's head for improved spatial resolution. Operating at the minimum radius ...

Journal: :Applied optics 2007
Jui-che Tsai Chun-Yi Yin Chia-Wei Sun Ming C Wu

A theoretical model based on Fourier optics and the power-coupling overlap integral is built to investigate the interchannel response in a micro-electro-mechanical systems 1xN(2) wavelength-selective switch. The simulation results demonstrate that the interchannel response depends significantly on the output port location and the radius of curvature of the micromirrors. For the output originall...

2001
P. TENENBAUM K. BANE L. ERIKSSON R. K. JOBE D. MCCORMICK C. K. NG T. O. RAUBENHEIMER M. C. ROSS G. STUPAKOV D. WALZ P. Tenenbaum K. Bane L. Eriksson R. K. Jobe D. McCormick C. K. Ng T. O. Raubenheimer M. C. Ross G. Stupakov D. Walz

We report on a series of measurements of the transverse wakefield from tapered collimators. The collimators were designed to principally present a geometric impedance to the beam, and to minimize impedances from resistivity or surface features; in addition, the geometries of the collimators were selected to permit examination of the scaling behavior of the wakefield due to collimator taper angl...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید