نتایج جستجو برای: cruciate retaining
تعداد نتایج: 27210 فیلتر نتایج به سال:
BACKGROUND This study compared clinical and radiological results between robotic total knee arthroplasty (TKA) and conventional TKA with a cruciate-retaining implant at 10-year follow-up. The hypothesis was that robotic TKA would allow for more accurate leg alignment and component placement, and thus enhance clinical and radiological results and long-term survival rates. METHODS A total of 11...
OBJECTIVES Posterior condylar offset (PCO) and posterior tibial slope (PTS) are critical factors in total knee arthroplasty (TKA). A computational simulation was performed to evaluate the biomechanical effect of PCO and PTS on cruciate retaining TKA. METHODS We generated a subject-specific computational model followed by the development of ± 1 mm, ± 2 mm and ± 3 mm PCO models in the posterior...
Fixed flexion contracture can present a technical challenge in total knee arthroplasty. Various techniques of addressing these deformities have been described including additional bony resection, ligamentous releases, and the use of increasing constraint. We retrospectively reviewed the clinical outcomes of 40 patients (52 knees) with fixed flexion contracture greater than or equal to 20 degree...
Using a new, non-invasive method, we measured the patellofemoral force (PFF) in cadaver knees mounted in a rig to simulate weight-bearing. The PFF was measured from 20 degrees to 120 degrees of flexion before and after implanting three designs of knee prosthesis. Medial unicompartmental arthroplasty with a meniscal-bearing prosthesis and with retention of both cruciate ligaments caused no signi...
PURPOSE To review 6 cases of periprosthetic distal femoral fracture during total knee arthroplasty (TKA). METHODS Of 778 women and 691 men who underwent primary TKAs using posterior-stabilised (n=1240), cruciate-retaining (n=165), or semiconstrained (n=64) implant, 5 women and one man with a mean age of 73.3 years and a mean body mass index of 31.6 kg/m(2) sustained an intra-operative peripro...
Open Access This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the source is credited. DOI 10.3109/17453674.2013.752693 A 66-year old woman (BMI 36) presented for routine followup after undergoing total knee arthroplasty (TKA) in the right knee 12 years ...
The objective of this study was to determine if consistent posterior femoral rollback of an asymmetrical posterior cruciate retaining (PCR) total knee arthroplasty was mostly influenced by the implant design, surgical technique, or presence of a well-functioning posterior cruciate ligament (PCL). Three-dimensional femorotibial kinematics was determined for 80 subjects implanted by 3 surgeons, a...
Instability is an important cause of failure following total knee arthroplasty. Increasing component constraint may reduce instability, but doing so also can cause increased forces to be transmitted to fixation and implant interfaces, which may lead to premature aseptic loosening. Constraint is defined as the effect of the elements of knee implant design that provides the stability needed to co...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید