نتایج جستجو برای: dose calculation

تعداد نتایج: 408802  

Journal: :jentashapir journal of health research 0
tahmasebi biragani tahmasebi biragani tahmasebi biragani mansur zabihzadeh hojatolah shahbazian mozafar naserpur

background when a primary radiation interacts with a medium, the secondary radiations are produced, that the contribution of these secondary radiation should considered in the calculation of dose. build-up factor is a dosimetric correction factor to assume effect of secondary radiation in calculation of dose. calculation of this factor is very difficult and time consuming. due to significance o...

2013
JR Sykes R Lindsay G Iball DI Thwaites

The use of Cone beam CT (CBCT) systems for Image Guided Radiotherapy is rapidly expanding in the developed world. With its use comes concern for the increased risks of additional radiation exposure. Quantification of the imaging dose is necessary in order to report, optimise and justify CBCT exposures. This article reviews the current methods of dose measurement and calculation including dose m...

2016
Bagher Farhood Mohammad Taghi Bahreyni Toossi Shokouhozaman Soleymanifard

Introduction Wedge modifiers are commonly applied in external beam radiotherapy to change the dose distribution corresponding to the body contour and to obtain a uniform dose distribution within the target volume. Since the radiation dose delivered to the target must be within ±5% of the prescribed dose, accurate dose calculation by a treatment planning system (TPS) is important. The objective ...

M. Shahriari, M.R. Ay, P. Ghafarian, S. Sarkar,

Background: CT is a diagnostic imaging modality giving higher patient dose in comparison with other radiological procedures, so the calculation of organ dose in CT exams is very important. While methods to calculate the effective dose have been established (ICRP 26 and ICRP 60), they depend heavily on the ability to estimate the dose to radiosensitive organs from the CT procedure. However, dete...

Introduction: In radiotherapy treatment planning system (TPS), basic input is the data from computed tomography (CT) scan, which takes into account the effect of inhomogeneities in dose calculations. Measurement of CT numbers may be affected by scanner-specific parameters. Therefore, it is important to verify the effect of different CT scanning protocols on Hounsfield unit (HU) and its impact o...

Journal: :iranian journal of medical physics 0
ahad ollah ezzati faculty of physics, university of tabriz, tabriz, iran seyed rabi mahdavi department of medical physics, iran university of medical sciences, tehran, iran

introduction in this study, we aimed to calculate dose enhancement factor (def) for gold (au) and iron (fe) nanoparticles (nps) in brachytherapy and teletherapy, using monte carlo (mc) method. materials and methods in this study, a new algorithm was introduced to calculate dose enhancement by aunps and fenps for iridium-192 (ir-192) brachytherapy and cobalt-60 (co-60) teletherapy sources, using...