نتایج جستجو برای: dosimeter

تعداد نتایج: 2113  

2012
B. Azadbakht

The purpose of this study was to evaluate dependence of PAGAT polymer gel dosimeter 1/T2 on different electron and photon energies for a standard clinically used Co therapy unit and an electa linear accelerator.Using MRI, the formulation to give the maximum change in the transverse relaxation rate R2(1/T2) was determined to be 4.5% N,N'-methylen-bis-acrylamide(bis), 4.5% acrylamid(AA), 5% gelat...

Journal: :The European respiratory journal 2000
H C Siersted C M Walker A D O'Shaughnessy A R Willan E M Wiecek M R Sears

In the European Community Respiratory Health Study (ECRHS), airway responsiveness to methacholine was determined using the Mefar dosimeter protocol. Elsewhere, the 2-min tidal breathing method has become the preferred standardized method. The relationship between measurements of responsiveness by these two methods is not well established. This study measured airway responsiveness to methacholin...

2006
Alfio V. Parisi Michael G. Kimlin

Polysulphone has been widely used as a dosimeter to quantify personal solar UV exposures to humans during normal daily activities. In summer at sub-tropical and tropical latitudes, the dynamic range for UV exposures allows the use of the polysulphone to measure solar UV over periods of approximately three to six hours. The use of mesh as a filter over the polysulphone has been previously report...

2013
C - S Wuu Y Xu X Qian J Adamovics E Cascio

Monte Carlo water-equivalence study of two PRESAGE® formulations for proton beam dosimetry T Gorjiara, Z Kuncic, J Adamovics and C Baldock 2013 J. Phys.: Conf. Ser. 444 012090 PRESAGE® is a radiochromic solid dosimeter which shows promising potential for 3D proton beam dosimetry. Since an idea dosimeter should be water-equivalent, total depth dose distributions in two PRESAGE® formulations irra...

2008
J. B. Davies C. Baldock

Spectrophotometric measurements of the Fricke–gelatin–xylenol orange (FGX) gel dosimeter demonstrated reproducible linear dose response up to 25Gy. However, oxidation processes continue post-irradiation, affecting the response of this dosimetry system. Additional oxygenation during preparation increases the sensitivity of the gel but does not improve the auto-oxidation stability of the dosimete...

Journal: :The Journal of the Acoustical Society of America 2012
Steven Ryherd Mendel Kleiner Kerstin Persson Waye Erica E Ryherd

In recent years, interest in personal noise exposure has expanded beyond a workplace safety measure to become an effective means of investigating physiological effects of the acoustic environment on an individual. This work investigates the effects of the wearer's voice as a possible dominant sound source on body-mounted noise dosimeters and develops methods to improve the application of dosime...

Journal: :Journal of the Ceramic Society of Japan 2013

Journal: :Brazilian Journal of Radiation Sciences 2023

Radiation dosimetry has the purpose of quantifying dose received by occupationally exposed individual. The device used in this process is called a dosimeter, dosimeter can be different situations, for example, to quantify fingers ring model extremity, which focus work. In Brazil, we still do not have standards calibration extremity dosimeters, therefore, work, CASEC recommendations were used, a...

Journal: :Annals of allergy, asthma & immunology : official publication of the American College of Allergy, Asthma, & Immunology 2012
Donald W Cockcroft Beth E Davis

Whenmethacholine is inhaledwith total lung capacity inhalations, which is the recommended inhalation pattern for the 5-breath dosimeter method,1 as many as a quarter of asthmatic patients can have a false-negative test result.2 It has been suggested to us that high forced expiratory volume in 1 second (FEV1) could explain negative (dosimeter) methacholine test results in patients with asthma. W...