نتایج جستجو برای: dosimetry linear accelerator add on mlc recommissioning

تعداد نتایج: 8622156  

Introduction: To estimate the accuracy levels of Lagrange, Newton backward interpolation, and linear interpolation methods in estimating the output factors for square fields used in linear accelerator for 6 MV photons at various depths. Materials and Methods: Ionization measurements were carried out in radiation field analyzer in linear accelerator for 6 MV beams at the depths of 5 and 10 cm by...

Introduction: The utilization of high-energy photons in the medical linear accelerator can lead to photoneutron production. This study aimed to evaluate the effect of the physical components of the head, including flattening filter (FF) andmultileaf collimator (MLC), as well as the dependence of therapeutic field size on the photoneutron spectrum, dose, and flux. <str...

Journal: :IOP Conference Series: Materials Science and Engineering 2021

The work presents application of previously proposed approach for transverse profile forming high energy electron beams with plastic samples made using 3D printing technology. collimator PLA (polylactide) is designed and produced in a frame this work. results 6 MeV beam clinical linear accelerator Elekta Synergy presented. Obtained comparison data from XiO dosimetry planning system shows good a...

Journal: :Sensors and Actuators A-physical 2021

The Investigations of this article focus on the response Al2O3:C and Al2O3:C,Mg radioluminescence films for medical dosimetry in various MV photon beams. A system was configured using a scientific camera, attached to head linear accelerator (LINAC), facing beam’s isocenter, where were placed. By appropriate filter lens it is possible measure real time two-dimensional dose-rate distributions. ke...

Journal: :iranian journal of radiation research 0
m. momennezhad nuclear medicine research center, emam reza hospital, mashhad university of medical sciences, mashhad, iran m.t. bahreyni toosi medical physics research center, mashhad university of medical sciences, mashhad, iran r. sadeghi nuclear medicine research center, emam reza hospital, mashhad university of medical sciences, mashhad, iran h. gholamhoseinian department of medical physics, medical school, mashhad university of medical sciences, mashhad, iran sh. nasseri department of medical physics, medical school, mashhad university of medical sciences, mashhad, iran

background: the presence of a wedge filter in the beam trajectory can modify the beam quality and cause some changes in the dosimetry parameters which are usually difficult to be measured directly and accurately. material and methods: in this study the mcnp-4c monte carlo code was used to simulate the 9 mv photon beam generated by a linear accelerator. upon getting a good agreement between the ...

Journal: :Physics in medicine and biology 2008
Eric E Klein Milos Vicic Chang-Ming Ma Daniel A Low Robert E Drzymala

Treating shallow tumors with a homogeneous dose while simultaneously minimizing the dose to distal critical organs remains a challenge in radiotherapy. One promising approach is modulated electron radiotherapy (MERT). Due to the scattering properties of electron beams, the commercially provided secondary and tertiary photon collimation systems are not conducive for electron beam delivery when s...

2012
Khosrow Javedan Geoffrey G. Zhang Sarah Hoffe Vladimir Feygelman Kenneth Forster

The build-up dose in the megavoltage photon beams can be a limiting factor in intensity-modulated radiation therapy (IMRT) treatments. Excessive surface dose can cause patient discomfort and treatment interruptions, while underdosing may lead to tumor repopulation and local failure. Dose in the build-up region was investigated for IMRT delivery with solid brass compensator technique(compensator...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید