نتایج جستجو برای: fluorimetric technique

تعداد نتایج: 612336  

Journal: :Diagnostic microbiology and infectious disease 2013
Marcele N Rocha Célia M Corrêa Maria N Melo Stephen M Beverley Olindo Assis Martins-Filho Ana Paula Madureira Rodrigo P Soares

Fluorescent and colorimetric reporter genes are valuable tools for drug screening models, since microscopy is labor intensive and subject to observer variation. In this work, we propose a fluorimetric method for drug screening using red fluorescent parasites. Fluorescent Leishmania amazonensis were developed after transfection with integration plasmids containing either red (RFP) or green fluor...

Journal: :Journal of chromatographic science 2012
Sevgi Tatar Ulu

A high-performance liquid chromatographic (HPLC) method is described for the determination of duloxetine hydrochloride in capsules. The method was based on pre-column derivatization with 4-chloro-7-nitrobenzo-2-oxa-1,3-diazole using the fluorimetric detection technique. Duloxetine hydrochloride was analyzed by HPLC using an Inertsil C18 column (5 μm, 150 × 4.6 mm) and mobile phase consisted of ...

Journal: :Proceedings of the Association of Clinical Biochemists 1962

A. Kumar, K.P. Mishra, P. Sharma, P.K. Meher, Y.P. Gautam,

Background: Uranium poses both chemical and radiological hazard to the living system. Drinking water from river is one of the major sources of uranium intake. Dissolution of minerals, washout from rain water, rock-water interaction, agricultural run off, and industrial disposals are some of the sources of uranium in river water system. Present study was aimed to determine the uranium in the wat...

1996
Joan-Albert Sanchez-Cabeza

The determination of radium and/or uranium concentrations in natural waters is useful in a wide range of environmental studies. In this work, a low-background liquid scintillation system (Wallac, Quantulus 1220) was used to determine simultaneously 226Ra and uranium (total) activities in natural water samples. Sample preparation involved filtration and 1 : 10 concentration by evaporation. Then,...

Journal: :Analytical and bioanalytical chemistry 2012
I M Perez de Vargas-Sansalvador C Fay M D Fernandez-Ramos D Diamond F Benito-Lopez L F Capitan-Vallvey

A portable instrument for oxygen determination, based on the quenching of phosphorescent octaethylporphyrin by gaseous O(2), has been developed using the fluorimetric paired emitter-detector diode technique (FPEDD). The instrument configuration consists of two light-emitting diodes (LEDs) facing each other, with an interchangeable support containing a phosphorescent membrane in between, in whic...

Journal: :European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies 1996
G Lefevre C Bonneau S Rahma B Chanu D Brault R Couderc J Etienne

We describe a method for the measurement of protein-bound malondialdehyde with the thiobarbituric acid reaction in human plasma using second-derivative spectrophotometry. Calibration was done by spectrum height measurement from the baseline at 532 nm. The data were compared with those obtained by using conventional absorbance and fluorimetric measurements. The results were linear from 0.2 to 80...

2015
Ming La Lin Liu Bin-Bin Zhou

MicroRNAs (miRNAs) are small endogenous non-coding RNAs of ~22 nucleotides that play important functions in the regulation of many biological processes, including cell proliferation, differentiation, and death. Since their expression has been in close association with the development of many diseases, recently, miRNAs have been regarded as clinically important biomarkers and drug discovery targ...

Journal: :Molecular bioSystems 2011
Marijana Radić Stojković Snežana Miljanić Katarina Mišković Ljubica Glavaš-Obrovac Ivo Piantanida

At submicromolar concentrations two novel phenanthridine biguanides exhibit distinctly different spectroscopic signals for dGdC and dAdT sequences, respectively, by opposite fluorimetric changes (quenching for dGdC and increase for dAdT) and especially the bis-biguanide derivative gives an opposite ICD response (negative ICD for dGC and strong positive for dAdT). This specific signalling was ex...