نتایج جستجو برای: frequency transformer

تعداد نتایج: 494113  

2011
Amit Gupta Ranjana Singh

Transformers are normally designed and built for use at rated frequency and perfect sinusoidal load current. A non-linear load on a transformer leads to harmonic power losses which cause increased operational costs and additional heating in power system components. It leads to higher losses, early fatigue of insulation, premature failure and reduction of the useful life of the transformer. To p...

2012
R.Samuel Rajesh Babu Joseph Henry

This paper presents a comparative analysis of DC-DC Converters for Renewable Energy System. It has been proved that DC-DC converter with transformer is suitable for Electrolyser application. Due to high input and output voltage differences, the topologies with a high frequency voltage matching transformer are analyzed. The comparative analysis is done with and without Transformer topology in or...

Journal: :IEEE Trans. Industrial Electronics 1999
Yueh-Ru Yang Chern-Lin Chen

The steady-state oscillation of a zero-voltageswitching clamped-voltage self-oscillating ballast driven by a saturable transformer is analyzed and simulated. Its selfoscillating operation is divided into six stages according to the hysteresis B–H loop of saturable transformer cores. Stage-wise circuit analysis shows the saturable transformer limits the lamp current and dominates the switching f...

Journal: :IEEE Trans. Industrial Electronics 2003
Yungtaek Jang Milan M. Jovanovic

A high-performance contactless electrical energy transmission (CEET) technique which employs the inductive energy transmission principle is described. The proposed technique enables the implementation of high-efficiency high-power-density fully regulated CEET systems suitable for applications with a wide input and load range. A high efficiency of the system is achieved by recovering the energy ...

2013
Tang Jinrui Yin Xianggen Zhang Zhe

Theoretical research and equipment development of traveling-wave fault location seriously depend on digital simulation. Meanwhile, the fault-generated transient traveling wave must be transferred through transmission line, mutual inductor and secondary circuit before it is used. So this paper would maily analyze and summarize the modeling technology of transmission line and mutual inductor on t...

2017
Giovanni De Carne Zhixiang Zou Giampaolo Buticchi Marco Liserre Yongheng Yang

Renewable energy resources and new loads—such as electric vehicles—challenge grid management. Among several scenarios, the smart transformer represents a solution for simultaneously managing lowand medium-voltage grids, providing ancillary services to the distribution grid. However, unlike conventional transformers, the smart transformer has a very limited overload capability, because the junct...

Journal: :مهندسی قدرت ایران 0
reza shariatinasab university of birjand, iran z ejtemaee university of birjand, iran j gholinezhad university of birjand, iran

power system overvoltages due to switching, lightning and other disturbances are the main problem for designers of the power transformers. once some frequencies of the incoming surges match with some of the natural frequencies of transformer winding, the resonance phenomenon is expected in transformer winding. the resonant overvoltages may destroy the insulation between turns and cause to insul...

In this paper, a new structure of HFTI-qZS-CMI has been proposed. The proposed structure is capable of generating high-voltage for medium to high power applications. By adding a switch, a capacitor and a high-frequency transformer and also eliminating an inductor from each qZS-CMI cell, the HFTI-qZS-CMI structure will be created. Using the high-frequency transformer in the proposed structure, l...

2011
Chong Ryol Park Ki Hwan Eom

This paper describes a metal mount RFID tag that works reliably on metallic surfaces. The method proposes the use of commercial label type RFID tags with 2.5 mm thick Styrofoam103.7 with a relative permittivity of 1.03 attached on the back of the tag. In order to verify the performance of the proposed method, we performed experiments on an electric transformer supply chain system. The experimen...

2015
D. Vidal J. Pedra

Airport ground lighting (AGL) systems provide visual reference to aircrafts during airport operations. In AGL systems, constant current regulators feed a beacon circuit supplied through isolation transformers. Component modeling is necessary to simulate AGL systems, and thus characterize and predict their behavior. This paper presents an isolation transformer model including transformer core sa...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید