نتایج جستجو برای: gafchromic film stereotactic radiotherapy
تعداد نتایج: 159884 فیلتر نتایج به سال:
PURPOSE To study EBT3 GafChromic film in low-energy protons, and for comparison purposes, in a reference (60)Co beam in order to use it as a calibrated dosimetry system in the proton irradiation facility under construction within the framework of the Oncological Therapy with Protons (TOP)-Intensity Modulated Proton Linear Accelerator for RadioTherapy (IMPLART) Project at ENEA-Frascati, Italy. ...
The location and field size of the incident X-ray beam in panoramic dental radiography cannot be ascertained visually most of the time. However, these parameters are needed for quality control and dosimetry determination. To alleviate this problem, we tested GafChromic XR-QA film on two panoramic systems. For each system, we used the length of a cross-sectional image of the incident beam and th...
Gafchromic XR type-R radiochromic film is a relatively new product designed for use at clinical diagnostic x-ray energies both qualitatively and quantitatively. This short note investigates the energy response characteristics of this high-sensitivity radiochromic film for both diagnostic and therapeutic x-ray energies. Results are also compared to conventional silver halide x-ray film for energ...
PURPOSE To study the effect of different filters on the dose response curves of the Gafchromic XRQA2 film. To measure the kV XVI cone-beam CT (CBCT) surface dose received during 3D and 4D imaging protocols in three body regions (head and neck, chest and pelvis). METHODS GafChromic XR- QA2 film (International Specialty Products, Wayne, NJ) dose response curves were generated for three irradiat...
This study examined the response characteristics of three commercially available radiochromic films when exposed to low energy (50 kVp) X-rays. The aim was to evaluate the films for potential use in 2D dosimetry for a low-kV intraoperative radiotherapy (IORT) device known as the ‘Intrabeam’. Dose-response relationships were obtained for Gafchromic EBT, XR-RV2, and XR-QA film in water at several...
The response of radiochromic film, GafChromic EBT, was investigated for dependence on x-ray beam energy using a previously reported real-time optical readout approach. X-ray beams of energy from 75 kVp to 18 MV were employed. The dose-induced change in optical density for the EBT film was compared to values obtained for GafChromic HS and MD-55 films, exposed under the same conditions. All respo...
AIM Complex geometry of breast tissue causes perturbation in dose distribution. This problem can beget overdose or under-dose points in match region of three fields. The aim of this study is to create dose homogeneity distribution in match region between tangential and supraclavicular fields (SCF) with Gafchromic external beam therapy (EBT) film. MATERIALS AND METHODS In this study, an anatom...
The accuracy of the dose planning system (Leksell GammaPlan) used in Gamma Knife (model-B) radiosurgery was verified using both the GafChromic films MD-55 (improved) and the EGS4 Monte Carlo technique. The Monte Carlo technique was employed to calculate the dose distribution along the x-, y- and z-axes when a single shot with opening of all 201 sources was delivered at the centre of a simulated...
PURPOSE To present EBT2 film verification of treatment planning with the eXtend System, a relocatable frame system for multiple-fraction or serial multiple-session radiosurgery. METHODS A human head shaped phantom simulated the verification process for fractionated Gamma Knife (GK) treatment. Phantom preparation for eXtend Frame based treatment planning involved creating a dental impression, ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید