Purpose: It is essential to maintain dynamic stability during walking to perform daily tasks independently. The present study aimed at comparing the spatiotemporal parameters and the values of the vertical ground reaction force (vGRF) as well as determining the time to reach them in ankle-sprain coper and healthy athletes during the stance phase of gait. Methods: A total of 28 female universit...
A new gait training device has been developed to provide auditory feedback of knee angle information to above-knee and hip disarticulation amputees. Traditionally, new amputees have relied on visual feedback of knee position during gait training (van Griethuysen, 1979). This auditory feedback system eliminates the need for visual feedback by providing a frequency encoded tone corresponding to k...
The automatic suspension device (REHABOT) suspends the patient's body in a standing position allowing the patient to walk around the circular handrail without forward propulsion. Reduction of body weight is accurately maintained automatically while safely supporting the patient. The device was used for 23 patients with orthopaedic disorders or central nervous system disorders who were chosen be...
This paper presents algorithms for detection of gait initiation and termination using wearable inertial measurement units and pressure-sensitive insoles. Body joint angles, joint angular velocities, ground reaction force and center of plantar pressure of each foot are obtained from these sensors and input into supervised machine learning algorithms. The proposed initiation detection method reco...
Real-time detection of gait events can be applied as a reliable input to control drop foot correction devices and lower-limb prostheses. Among the different sensors used to acquire the signals associated with walking for gait event detection, the accelerometer is considered as a preferable sensor due to its convenience of use, small size, low cost, reliability, and low power consumption. Based ...
BACKGROUND Crouch gait is a major sagittal plane deviation in children diagnosed with cerebral palsy (CP). It is defined as a combination of excessive ankle dorsiflexion and knee and hip flexion throughout the stance phase. To the best of our knowledge, functional electrical stimulation (FES) has not been used to decrease the severity of crouch gait in CP subjects and assist in achieving lower ...
One of the challenges that any powered lower limb orthotic or prosthetic device must address for activities in the real world is its ability to recognize gait modes (level ground walking, stairs, ramps, etc.) and adapt to mode changes promptly. There are two critical aspects of this problem. First, the gait mode has to be recognized at the earliest possible time to prevent potential misfiring (...
BACKGROUND The purpose of the study was to examine the effect of a foot-worn biomechanical device on the clinical measurements and gait patterns of patients with total hip arthroplasty (THA). METHODS Nineteen patients, up to 3 months post-THA, were enrolled to the study. Patients underwent a computerized gait analysis to calculate spatiotemporal parameters and completed the Western Ontario an...