نتایج جستجو برای: good corrosion resistance

تعداد نتایج: 808226  

Journal: :journal of dentistry, tehran university of medical sciences 0
farzin heravi department of orthodontics, school of dentistry mashad university of medical sciences, mashhad, iran. mohamad hadi moayed department of materials and metallurgical engineering, ferdowsy university, mashhad, iran. nima mokhber department of orthodontics, academic center of education, culture and research (acecr), mashhad, iran.

the commonly used nickel-titanium (niti) archwires in orthodontic treatment are often exposed to fluoride-containing mouthwashes. the aim of this in-vitro study was to evaluate and compare the corrosion resistance of three commercially available niti archwires exposed to 0.05 wt% and 0.2 wt% fluoride mouthwashes.three different types of niti archwires, 0.016″ in diameter, from dentaurum, global...

Journal: :Journal of the mechanical behavior of biomedical materials 2011
J Fornell N Van Steenberge A Varea E Rossinyol E Pellicer S Suriñach M D Baró J Sort

The effects of annealing treatments on the microstructure, elastic/mechanical properties, wear resistance and corrosion behavior of rod-shaped Ti40Zr10Cu38Pd12 bulk glassy alloys, synthesized by copper mold casting, are investigated. Formation of ultrafine crystals embedded in an amorphous matrix is observed for intermediate annealing temperatures, whereas a fully crystalline microstructure dev...

2014
J. Porcayo-Calderón O. Sotelo-Mazón M. Casales-Diaz J. A. Ascencio-Gutierrez V. M. Salinas-Bravo L. Martinez-Gomez

Corrosion behavior of Ni20Cr coatings deposited by HVOF (high velocity oxygen-fuel) process was evaluated in ZnCl2-KCl (1 : 1 mole ratio) molten salts. Electrochemical techniques employed were potentiodynamic polarization curves, open circuit potential, and linear polarization resistance (LPR) measurements. Experimental conditions included static air and temperatures of 350, 400, and 450°C. 304...

2003
Zaki Ahmad

Scandium-reinforced aluminum alloys represent a new generation of high-performance alloys that display numerous advantages over high-strength aluminum alloys. Scandium-reinforced alloys are much stronger than other high-strength alloys, exhibit significant grain refinement, strengthen welds, and eliminate hot cracking in welds. These alloys also exhibit a good resistance to corrosion as shown b...

2015
Yu-Mei Han X.-Grant Chen

Aluminum based metal matrix composites (MMCs) have received considerable attention in the automotive, aerospace and nuclear industries. One of the main challenges using Al-based MMCs is the influence of the reinforcement particles on the corrosion resistance. In the present study, the corrosion behavior of Al-B₄C MMCs in a 3.5 wt.% NaCl solution were investigated using potentiodynamic polarizat...

Journal: :international journal of iron & steel society of iran 2015
m. atapour m. m dana f. ashrafizadeh

aisi 304l austenitic stainless steel with different grain sizes of 0.5 -12 μm was obtained through the martensiticprocess. corrosion behavior of different samples was investigated in a 0.5m hcl solution using open circuitpotential, potentiodynamic polarization and electrochemical impedance spectroscopy tests. also, the correlationbetween the grain size and pitting corrosion resistance was asses...

2016
Yunze Xu Kaiqiang Li Liang Liu Lujia Yang Xiaona Wang Yi Huang

In this paper, a new kind of carbon steel (CS) and stainless steel (SS) galvanic sensor system was developed for the study of rebar corrosion in different pore solution conditions. Through the special design of the CS and SS electronic coupons, the electronic resistance (ER) method and zero resistance ammeter (ZRA) technique were used simultaneously for the measurement of both the galvanic curr...

Journal: :Chemical communications 2015
Hsiu-Hui Chen Kung-Chin Chang Chien-Ming Chu Hsu-Heng Hung Min-Hsiang Hsu Yu-Chun Hung Chien-Shiang Wang Jui-Ming Yeh

A discotic liquid crystal (DLC), HBC-C12, coating was successfully applied to improve the corrosion resistance of an iron surface. The iron surface with the DLC-coating exhibited improved corrosion resistance in various environments, including exposure to air and solutions with different pH values. To the best of our knowledge, studies regarding corrosion protection using DLCs have never been r...

2015
Xurong Li Hongguang Ji Shuang You

Shaft lining concrete itself has a certain degree of initial damage before being corroded by sulfate. In order to study the resistance of the concrete of the initial damage in different corrosion solution concentration of sulfate, samples of concrete without initial damage, loaded 50% ultimate load and loaded 70% ultimate load with initial damage concrete were selected and studied their corrosi...

2011
W. WALKE

The purpose of the tests was to determine whether and how sterilisation process of samples made of AISI 316L stainless steel with diff erent strain impacts their corrosion resistance. Tests were made on steel samples that had been electrochemically polished in order to assure proper surface roughness. In order to evaluate the infl uence of sterilisation on physical and chemical properties of st...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید