نتایج جستجو برای: heart mri t2

تعداد نتایج: 511078  

2018
Yingqiu Song Beth Erickson Xiaojian Chen Guiling Li Gang Wu Eric Paulson Paul Knechtges X. Allen Li

Background Accurate delineation of the gross tumor volumes (GTV) is a prerequisite for precise radiotherapy planning and delivery. Different MRI sequences have different advantages and limitations in their ability to discriminate primary cervical tumor from normal tissue. The purpose of this work is to determine appropriate MRI techniques for GTV delineation for external-beam radiation therapy ...

Journal: :Circulation. Cardiovascular imaging 2009
David E Sosnovik Matthias Nahrendorf Peter Panizzi Takashi Matsui Elena Aikawa Guangping Dai Ling Li Fred Reynolds Gerald W Dorn Ralph Weissleder Lee Josephson Anthony Rosenzweig

BACKGROUND The ability to image cardiomyocyte (CM) apoptosis in heart failure could facilitate more accurate diagnostics and optimize targeted therapeutics. We thus aimed to develop a platform to image CM apoptosis quantitatively and specifically in heart failure in vivo. The myocardium in heart failure, however, is characterized by very low levels of CM apoptosis and normal vascular permeabili...

2011
Taigang He Yanqiu Feng Ankur Gulati Dudley J. Pennell David N. Firmin

Introduction: Myocardial T2* measurement is a valuable tool for non-invasive assessment of tissue iron overload which can prevent disease in thalassemia patients (1). For the heavily iron loaded heart, T2* is substantially shortened (<10ms) and the signal to noise ratios (SNRs) of later echo images are usually very low (2). Various signal processing techniques have been proposed for denoising M...

2015
Han W. Kim Lowie Van Assche Robert B. Jennings W. Benjamin Wince Christoph J. Jensen Wolfgang G. Rehwald David C. Wendell Lubna Bhatti Deneen M. Spatz Michele A. Parker Elizabeth R. Jenista Igor Klem Anna Lisa C. Crowley Enn-Ling Chen Robert M. Judd Raymond J. Kim

RATIONALE After acute myocardial infarction (MI), delineating the area-at-risk (AAR) is crucial for measuring how much, if any, ischemic myocardium has been salvaged. T2-weighted MRI is promoted as an excellent method to delineate the AAR. However, the evidence supporting the validity of this method to measure the AAR is indirect, and it has never been validated with direct anatomic measurement...

2014
Ananth Kidambi John D Biglands David M Higgins David P Ripley Arshad Zaman David A Broadbent Adam K McDiarmid Peter P Swoboda Tarique Al Musa Bara Erhayiem John P Greenwood Sven Plein

BACKGROUND Intramyocardial hemorrhage (IMH) identified by cardiovascular magnetic resonance (CMR) is an established prognostic marker following acute myocardial infarction (AMI). Detection of IMH by T2-weighted or T2 star CMR can be limited by long breath hold times and sensitivity to artefacts, especially at 3T. We compared the image quality and diagnostic ability of susceptibility-weighted ma...

2014
Qiao Han Yuchi Han Robert C Gorman Walter R Witschey

Background Spin lock or T1rho MRI methods may be very useful for assessing myocardial disease. Recently, we reported that there is significant low field relaxation dispersion in myocardial and fibrotic scar tissue during in vivo T1rho MRI, contributing to contrast enhancement compared to spin echo (T2) MRI. However, we also observed that differences in magnetic field susceptibility between the ...

2014
Sean C. Forbes Rebecca J. Willcocks William T. Triplett William D. Rooney Donovan J. Lott Dah-Jyuu Wang Jim Pollaro Claudia R. Senesac Michael J. Daniels Richard S. Finkel Barry S. Russman Barry J. Byrne Erika L. Finanger Gihan I. Tennekoon Glenn A. Walter H. Lee Sweeney Krista Vandenborne

INTRODUCTION Duchenne muscular dystrophy (DMD) is an X-linked recessive disorder that results in functional deficits. However, these functional declines are often not able to be quantified in clinical trials for DMD until after age 7. In this study, we hypothesized that (1)H2O T2 derived using (1)H-MRS and MRI-T2 will be sensitive to muscle involvement at a young age (5-7 years) consistent with...

A Hashemi, B Rahimi, M Noroozi, N Valizadeh, S Hejazi, Sh Nateghi, V Alinejad,

Abstract Background Iron overload is the main transfusion related side effects in patients with transfusion dependent hemoglobinopathies. Severe iron deposition in tissues leads to organ dysfunction. Many organs can be affected such as heart, liver, and endocrine organs. Cardiac failure and liver fibrosis are the consequent of Iron overload in transfusion dependent hemoglobinopathy. Magne...

Introduction: Nowadays applying computer in image processing is being improved revolutionary for solving medical images deficiencies. Image features that are analysis in image processing show image information. The aim of the present study was to find correlation between CT- scan and MRI images' features. Materials and Methods: After data acquisition, applying...

2010
Hee Kyung Kim Tal Laor Paul S Horn Brenda Wong

OBJECTIVE To determine the feasibility of using T2 mapping as a quantitative method to longitudinally follow the disease activity in children with Duchenne muscular dystrophy (DMD) who are treated with steroids. MATERIALS AND METHODS ELEVEN BOYS WITH DMD (AGE RANGE: 5-14 years) underwent evaluation with the clinical functional score (CFS), and conventional pelvic MRI and T2 mapping before and...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید