نتایج جستجو برای: hydrophilic intraocular lens
تعداد نتایج: 79317 فیلتر نتایج به سال:
purpose: to evaluate the predictability, efficacy, and safety of iris-claw artisanô phakic intraocular lenses for myopia. methods: through a prospective clinical study, 35 eyes of 21 patients with myopia from -5 to 26.5 diopters underwent implantation of the artisan lens. patients were examined 1, 3, and 7 days (all eyes); 1 month (28 eyes), 3 months (29 eyes), and 6 months (32 eyes) after the...
purpose: to describe a case with a rare complication of posterior chamber intraocular lens (pc-iol) implantation in a patient who had undergone extracapsular cataract extraction (ecce) two years before case report: a 80-year-old diabetic woman presented with an exposed pc-iol in her left eye with a history of mechanical trauma. slit-lamp examination revealed an extruded pc-iol lied on the anter...
purpose : to evaluate the near visual performance of an accommodative intraocular lens (iol) tetraflex, in comparison to a standard monofocal foldable iol in cataract surgery. setting: eye research center , farabi eye hospital , department of ophthalmology, tehran university of medical sciences, iran . methods : forty six eyes of 23 patients with cataract underwent phacoemulsification and accom...
Purpose To evaluate the influence of Intraocular Lens (IOL) material and design on Posterior Capsule Opacification (PCO) and Neodymium-YAG (Nd-YAG) rates in eyes implanted with different Posterior Chamber Intraocular Lenses (PC IOLs) designs at the end of uncomplicated cataract surgeries. Setting Oculus Eye Clinic, Bucharest, Romania. Design Retrospective, observational study. Methods Thi...
PURPOSE To compare the ongrowth of lens epithelial cells (LECs) on the anterior surface of 6 different hydrophilic intraocular lenses (IOLs). SETTING Medical University of Vienna, Department of Ophthalmology and Optometry, Vienna, Austria. METHODS Six models of hydrophilic IOLs were compared in this prospective study: Visionflex A-100 (Distra Softcryl), Rayner Centerflex 570H (Rayner), Coll...
The performance of an intraocular lens is determined by several factors such as the surgical technique, surgical complications, intraocular lens biomaterial and design, and host reaction to the lens. The factor indicating the biocompatibility of an intraocular lens is the behavior of inflammatory and lens epithelial cells. Hence, the biocompatibility of intraocular lens materials is assessed in...
purpose: to compare the effect of implantation of a single-piece hydrophilic foldable acrylic intraocular lens (iol) with rectangular optic edge and a single-piece polymethyl methacrylate (pmma) iol with rounded optic edges on posterior capsular opacification )pco(. methods: this randomized clinical trial study comprised 74 eyes with senile cataract in an otherwise normal eye in patients older ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید