نتایج جستجو برای: intensity focused ultrasound

تعداد نتایج: 461743  

2013
Thilo Hölscher Rema Raman David J Fisher Golnaz Ahadi Eyal Zadicario Arne Voie

The goal was to test the effects of various combinations of pulse widths (PW) and duty cycles (DC) on high-intensity focused ultrasound (HIFU)-induced sonothrombolysis efficacy using an in vitro flow model. An ExAblate™ 4000 HIFU headsystem (InSightec, Inc., Israel) was used. Artificial blood clots were placed into test tubes inside a human calvarium and exposed to pulsatile flow. Four differen...

2013
Yang Han Gary Yi Hou Shutao Wang Elisa Konofagou

Several ultrasound-based imaging modalities have been proposed for image guidance and monitoring of High-Intensity Focused Ultrasound (HIFU) surgery. However, accurate localization and characterization of the effective region of treatment (thermal lesion) remain the obstacles in the clinical implementation of HIFU ablation. Harmonic motion imaging for focused ultrasound (HMIFU) is a novel HIFU ...

2015
Michael Schwenke Jan Strehlow Sabrina Haase Christine Tanner Yoav Levy Tobias Preusser

Background/introduction Non-invasive ablation and hyperthermia treatments of abdominal organs using High Intensity Focused Ultrasound (HIFU) still impose severe challenges. Especially for liver and kidney treatments, the target motion and accessibility over the entire respiratory cycle make the application of HIFU difficult. To allow for a safe, effective, and efficient treatment, detailed plan...

Journal: :The Journal of the Acoustical Society of America 2013
Vera A Khokhlova Svetlana M Shmeleva Leonid R Gavrilov Eleanor Martin Neelaksh Sadhoo Adam Shaw

Considerable progress has been achieved in the use of infrared (IR) techniques for qualitative mapping of acoustic fields of high intensity focused ultrasound (HIFU) transducers. The authors have previously developed and demonstrated a method based on IR camera measurement of the temperature rise induced in an absorber less than 2 mm thick by ultrasonic bursts of less than 1 s duration. The goa...

2015
Xiangyun Liao Zhiyong Yuan Qianfeng Lai Jiaxiang Guo Qi Zheng Sijiao Yu Qianqian Tong Weixin Si Mingui Sun Alena Talkachova

PURPOSE In ultrasound-guided High Intensity Focused Ultrasound (HIFU) therapy, the target tissue (such as a tumor) often moves and/or deforms in response to an external force. This problem creates difficulties in treating patients and can lead to the destruction of normal tissue. In order to solve this problem, we present a novel method to model and predict the movement and deformation of the t...

Journal: :The Journal of the Acoustical Society of America 2006
Yufeng Zhou Liang Zhai Rebecca Simmons Pei Zhong

The acoustic fields of a high intensity focused ultrasound (HIFU) transducer operating either at its fundamental (1.1 MHz) or third harmonic (3.3 MHz) frequency were measured by a fiber optic probe hydrophone (FOPH). At 1.1 MHz when the electric power applied to the transducer was increased from 1.6 to 125 W, the peak positive/negative pressures at the focus were measured to be p(+) = 1.7-23.3 ...

Journal: :Physics in medicine and biology 2007
P Hariharan M R Myers R K Banerjee

A three-dimensional computational model is presented for studying the efficacy of high-intensity focused ultrasound (HIFU) procedures targeted near large blood vessels. The analysis applies to procedures performed at intensities below the threshold for cavitation, boiling and highly nonlinear propagation, but high enough to increase tissue temperature a few degrees per second. The model is base...

Journal: :Journal of endourology 2008
Peter Tsakiris Stefan Thüroff Jean de la Rosette Christian Chaussy

Developments in the technology applied to the field of minimally invasive surgery have led to the exploration of high-intensity focused ultrasound (HIFU) for the treatment of localized prostate cancer. Extensive research and continuous evolution have resulted in two commercially available HIFU devices: the Ablatherm and the Sonablate500. These devices are conceptually the same; however, specifi...

Journal: :The Journal of the Acoustical Society of America 2002
Alex Alaniz Faouzi Kallel Ed Hungerford Jonathan Ophir

The effects of high intensity focused ultrasound (HIFU)-induced continuously varying thermal gradients on sound ray propagation were modeled theoretically. This modeling was based on Fermat's variational principle of least time for rays propagating in a continuously varying thermal gradient described by a radially symmetric heat equation. Such thermal lenses dynamically affect HIFU beam focusin...

2016
Vera A. Khokhlova Petr V. Yuldashev Pavel B. Rosnitskiy Adam D. Maxwell Wayne Kreider Michael R. Bailey Oleg A. Sapozhnikov

Various clinical applications of high intensity focused ultrasound (HIFU) have different requirements on the pressure level and degree of nonlinear waveform distortion at the focus. Applications that utilize nonlinear waves with developed shocks are of growing interest, for example, for mechanical disintegration as well as for accelerated thermal ablation of tissue. In this work, an inverse pro...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید