نتایج جستجو برای: kvp accuracy

تعداد نتایج: 336094  

Journal: :Medical physics 2003
Walter Huda Anthony M Sajewicz Kent M Ogden David R Dance

Our purpose in this study was to investigate the image quality and absorbed dose characteristics of a digital mammography imaging system with a CsI scintillator, and to identify an optimal x-ray tube voltage for imaging simulated masses in an average size breast with 50% glandularity. Images were taken of an ACR accreditation phantom using a LORAD digital mammography system with a Mo target and...

Journal: :Physics in medicine and biology 2016
Han Chen Mats Danielsson Cheng Xu

We are developing a photon-counting spectral CT detector with a small pixel size of [Formula: see text] mm(2), offering a potential advantage for better visualization of small structures in pediatric patients. The purpose of this study is to determine the patient size dependent scanning parameters (kVp and mAs) for pediatric CT in two imaging cases: adipose imaging and iodinated blood imaging. ...

Journal: :Journal of radiological protection : official journal of the Society for Radiological Protection 2016
Ernest U Ekpo Suleman Bakhshi Elaine Ryan Peter Hogg Mark F McEntee

The aim of this work was to examine the peak entrance surface air kerma (peak ESAK) to the eyes during CT fluoroscopy lung biopsy, and the impact of lead glasses, exposure parameters, head rotation, and height on peak ESAK to the eyes. Two phantoms simulating the patient and radiologist were used, and 108 exposures were made using a 16-slice Toshiba Alexion CT scanner (Toshiba Medical Systems, ...

2017
Yi Hu Shinong Pan Xudong Zhao Wenli Guo Ming He Qiyong Guo

OBJECTIVE To evaluate orthopedic metal artifact reduction algorithm (O-MAR) in CT orthopedic metal artifact reduction at different tube voltages, identify an appropriate low tube voltage for clinical practice, and investigate its clinical application. MATERIALS AND METHODS The institutional ethical committee approved all the animal procedures. A stainless-steel plate and four screws were impl...

Journal: :Medical physics 2003
Emmanuel G Christodoulou Mitchell M Goodsitt Sandra C Larson Katie L Darner Jahangir Satti Heang-Ping Chan

A study was conducted to evaluate the radiation transmission through lead equivalent aprons that are used in a radiology department. A large area beam (poor geometry) was employed for the transmission measurements, and backscatter was simulated by placing 7" of Lucite behind each apron. Separate ionization chambers were used to measure the incident and transmitted x-ray beams. Transmission meas...

Journal: :Medical physics 2003
Eric A Berns R Edward Hendrick Gary R Cutter

Contrast-detail experiments were performed to optimize technique factors for the detection of low-contrast lesions using a silicon diode array full-field digital mammography (FFDM) system under the conditions of a matched average glandular dose (AGD) for different techniques. Optimization was performed for compressed breast thickness from 2 to 8 cm. FFDM results were compared to screen-film mam...

Journal: :Medical physics 2010
Amber J Gislason Andrew G Davies Arnold R Cowen

PURPOSE The aim of this research was to explore x-ray beam parameters with intent to optimize pediatric x-ray settings in the cardiac catheterization laboratory. This study examined the effects of peak x-ray tube voltage (kVp) and of copper (Cu) x-ray beam filtration independently on the image quality to dose balance for pediatric patient sizes. The impact of antiscatter grid removal on the ima...

2014
Chiao-Yun Chen Jui-Sheng Hsu Twei-Shiun Jaw Deng-Chyang Wu Ming-Chen Paul Shih Chien-Hung Lee Chao-Hung Kuo Yi-Ting Chen Ming-Lai Lai Gin-Chung Liu

OBJECTIVES To evaluate the diagnostic accuracy and the potential radiation dose reduction of dual-energy CT (DECT) for tumor (T) staging of colorectal cancer (CRC) using iodine overlay (IO) and virtual nonenhanced (VNE) images. MATERIALS AND METHODS This retrospective study included 103 consecutive patients who underwent nonenhanced CT and enhanced DECT for preoperative CRC staging. Enhanced ...

Journal: :International journal of advanced research 2022

The aim of a quality assurance (QA) program is to assist radio-diagnostic facility in consistently obtaining adequate radiological information with minimum dose and cost. An integrated part control (QC) which series examinations checks on equipment performance are undertaken, so that any changes can be objectively monitored remedies made. main objective the present work was carry out an indepen...

Journal: :AJNR. American journal of neuroradiology 2014
I Corcuera-Solano A M McLellan A H Doshi P S Pawha L N Tanenbaum

BACKGROUND AND PURPOSE Despite common use of CTP to assess cerebral hemodynamics in the setting of ischemia, concerns over radiation exposure remain. Our aim was to evaluate the efficacy of an adaptive 70-kVp (peak) whole-brain CTP protocol with variable sampling intervals and extended duration against an established fixed-sampling, limited-period protocol at 80 kVp. MATERIALS AND METHODS A r...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید