نتایج جستجو برای: mri based polymer gel dosimetry

تعداد نتایج: 3180930  

Journal: :iranian journal of radiation research 0
b. azadbakht department of nuclear engineering, shiraz university, shiraz, iran m.h. zahmatkesh novin medical research institute, tehran, iran k. hadad department of nuclear engineering, shiraz university, shiraz, iran s. bagheri novin medical research institute, tehran, iran

background: in this work investigation of the normoxic pagat polymer gel dosimeter such as sensitivity, the r2-dose response with post time and the percentage depth dose (pdd) of pagat polymer gel dosimeter have been undertaken. materials and methods: using mri, the formulation to give the maximum change in the transverse relaxation rate r2 was determined to be 4.5% n,n'-methylenbis- acryl...

2011
Timothy Olding Oliver Holmes Paul DeJean Kim B. McAuley Ken Nkongchu Giles Santyr L. John Schreiner

This paper explores the combination of cone beam optical computed tomography with an N-isopropylacrylamide (NIPAM)-based polymer gel dosimeter for three-dimensional dose imaging of small field deliveries. Initial investigations indicate that cone beam optical imaging of polymer gels is complicated by scattered stray light perturbation. This can lead to significant dosimetry failures in comparis...

M. Allahverdi M. Sedaghat M.H Zahmatkesh R. Jaberi Sh. Akhalghpoor

Introduction: Despite the fact that the clinical implementation of polymer gel dosimetry has been facilitated after the introduction of normoxic gels, there are still complications in its clinical routine use that are under investigation. In the current work, the feasibility of using a normoxic polymer gel dosimeter named MAGICA has been investigated for use in our clinical brachytherapy applic...

Azim Arbabi Bahram Bolouri Hasan Nedaie Ruhollah Ghahraman Asl

Introduction: Nowadays radiosensitive polymer gels are used as a reliable dosimetry tool for verification of 3D dose distributions. Special characteristics of these dosimeters have made them useful for verification of complex dose distributions in clinical situations. The aim of this work was to evaluate the capability of a normoxic polymer gel to determine electron dose distributions in differ...

2012
N. Gopishankar S. Vivekanandhan A. Jirasek S. S. Kale G. K. Rath Sanjay Thulkar R. K. Bisht

Gel dosimetry is a promising technique for the implementation of 3D dose verification within the radiation therapy clinic, since it is the only methodology which provides comprehensive 3D dose measurement of conformal treatments such as Intensity Modulated Radiation Therapy (IMRT), Stereotactic radiosurgery (SRS) and Stereotactic Radiotherapy (SRT), and volumetric arc therapies (VMAT). In polym...

ژورنال: سنجش و ایمنی پرتو 2019

Radiotherapy includes all methods that can deliver a particular amount of ionizing radiation to malignant tissues, assuming that minimal damage hurts healthy tissues. We are looking for a valuable and reliable method to measure absorbed dose and the ability to measure the distribution of absorbed dose in three dimensions which nowadays is one of the three-dimensional dosimetry methods in using ...

2011
N. Gopishankar Yoichi Watanabe Vivekanandhan Subbiah

One of treatment planning techniques with Leksell GammaPlan (LGP) for Gamma Knife stereotactic radiosurgery (GKSRS) uses multiple matrices with multiple dose prescriptions. Computational complexity increases when shots are placed in multiple matrices with different grid sizes. Hence, the experimental validation of LGP calculated dose distributions is needed for those cases. For the current stud...

2010
Yoichi Watanabe N. Gopishankar

Verification of the dose calculation model and the software used for treatment planning is an important step for accurate radiation delivery in radiation therapy. Using BANG3 polymer gel dosimeter with a 3 Tesla magnetic resonance imaging (MRI) scanner, we examined the accuracy of TomoTherapy treatment planning and radiation delivery. We evaluated one prostate treatment case and found the calcu...

Journal: :iranian journal of radiation research 0
f. pake department of medical physics and biomedical engineering, faculty of medicine, tehran university of medical sciences, tehran, iran a. takavar department of medical physics and biomedical engineering, faculty of medicine, tehran university of medical sciences, tehran, iran h.a. nedaie department of medical physics and biomedical engineering, faculty of medicine, tehran university of medical sciences, tehran, iran h.r. saligheh rad department of medical physics and biomedical engineering, faculty of medicine, tehran university of medical sciences, tehran, iran e. eqlimi department of medical physics and biomedical engineering, faculty of medicine, tehran university of medical sciences, tehran, iran v. vaezzadeh department of radiotherapy oncology, cancer research centre, cancer institute, tehran university of medical sciences, tehran, iran

background:  in this study a series of basic dosimetric properties of a low-density (ld) gel dosimeter are investigated. the dose response is studied regarding to linearity, sensitivity, dose-rate and energy dependence as well as lung tissue equivalence. materials and methods: the ld gel was made by mixing the polymer gel with expanded polystyrene spheres. energy dependence was studied at two d...

2016
Kai-Yuan Cheng Ling-Ling Hsieh Cheng-Ting Shih

Polymer gel dosimeters have been proven useful for dose evaluation in radiotherapy treatments. Previous studies have demonstrated that using a polymer gel dosimeter requires a 24 h reaction time to stabilize and further evaluate the measured dose distribution in two-dimensional dosimetry. In this study, the short-term stability within 24 h and feasibility of N-isopropylacrylamide (NIPAM) polyme...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید