نتایج جستجو برای: multi focus fan beam collimator

تعداد نتایج: 906544  

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 1992
T F Lang B H Hasegawa S C Liew J K Brown S C Blankespoor S M Reilly E L Gingold C E Cann

We have developed a prototype imaging system that can perform simultaneous x-ray transmission CT and SPECT phantom studies. This system employs a 23-element high-purity-germanium detector array. The detector array is coupled to a collimator with septa angled toward the focal spot of an x-ray tube. During image acquisition, the x-ray fan beam and the detector array move synchronously along an ar...

2009
Liling Xiao Cho-Kuen Ng Jeffery Claiborne Fritz Caspers

A rotatable collimator is proposed for the LHC phase II collimation upgrade. When the beam crosses the collimator, it will excite trapped modes that can contribute to the beam energy loss and power dissipation on the vacuum chamber wall. Transverse trapped modes can also generate transverse kicks on the beam and may thus affect the beam quality. In this paper, the parallel eigensolver code Omeg...

Background: This study aims to investigate radiation beam geometry of Cyberknife beam and change in dosimetric characteristics of six megavoltage (6MV) flattening filter free (FFF) beam after passing through high density cadmium free compensator alloy.Material and Methods: In this experimental study, changes in FFF beam dosimetric characteristics after passing through compensator alloy wa...

1997
Achim Schweikard

Treatment planning in radiosurgery and radiation therapy involves a large number of medical and technical constraints. The main technical constraints stem from the gantry kinematics and the type of collimator available. The gantry kinematics (i.e. number and spatial arrangement of movable joint axes) determines the type of motion which can be performed by the therapeutic beam. The collimator de...

2008
Gengsheng Lawrence Zeng

In single photon emission computed tomography (SPECT), pinhole and cone-beam collimators are used for small object imaging. It is accepted that a pinhole collimator should be used if the object is very small, and the cone-beam collimator should be used if the object is larger. This paper presents criteria to determine which collimation geometry is more advantageous in terms of spatial resolutio...

1999
M. Church A. I. Drozhdin A. Legan N. V Mokhov

Based on realistic Monte-Carlo simulations a two-stage beam collimation system is designed to minimize the beam loss in the Fermilab Tevatron for fixed target and collider Run II. Thin primary collimators are used to increase particle amplitude and their impact parameter on the downstream secondary collimators. This results in a significant reduction of the total beam loss in the machine, decre...

2012
Shinichiro Mori Toshiyuki Shirai Yuka Takei Takuji Furukawa Taku Inaniwa Yuka Matsuzaki Motoki Kumagai Takeshi Murakami Koji Noda

Our institution established a new treatment facility for carbon ion beam scanning therapy in 2010. The major advantages of scanning beam treatment compared to the passive beam treatment are the following: high dose conformation with less excessive dose to the normal tissues, no bolus compensator and patient collimator/multi-leaf collimator, better dose efficiency by reducing the number of scatt...

2015
Kwangzoo Chung Youngyih Han Jinsung Kim Sung Hwan Ahn Sang Gyu Ju Sang Hoon Jung Yoonsun Chung Sungkoo Cho Kwanghyun Jo Eun Hyuk Shin Chae-Seon Hong Jung Suk Shin Seyjoon Park Dae-Hyun Kim Hye Young Kim Boram Lee Gantaro Shibagaki Hideki Nonaka Kenzo Sasai Yukio Koyabu Changhoon Choi Seung Jae Huh Yong Chan Ahn Hong Ryull Pyo Do Hoon Lim Hee Chul Park Won Park Dong Ryul Oh Jae Myung Noh Jeong Il Yu Sanghyuk Song Ji Eun Lee Bomi Lee Doo Ho Choi

PURPOSE The purpose of this report is to describe the proton therapy system at Samsung Medical Center (SMC-PTS) including the proton beam generator, irradiation system, patient positioning system, patient position verification system, respiratory gating system, and operating and safety control system, and review the current status of the SMC-PTS. MATERIALS AND METHODS The SMC-PTS has a cyclot...

2001
C.-K. Ng T. O. Raubenheimer P. Tenenbaum

The performance of future linear colliders are limited by the effect of short-range collimator wakefields on the beam. The beam quality is sensitive to the positioning of collimators at the end of the linac. The determination of collimator wakefields has been difficult, largely because of the scarcity of measurement data, and of the limitation of applicability of analytical results to realistic...

نمودار تعداد نتایج جستجو در هر سال