نتایج جستجو برای: mv photon beam

تعداد نتایج: 199565  

Journal: :iranian journal of radiation research 0
a. mesbahi medical physics department, medical school, tabriz university of medical sciences- iran

background: monte carlo (mc) modeling of a linear accelerator is a prerequisite for monte carlo dose calculations in external beam radiotherapy. in this study, a simple and efficient model was developed for elekta sl-25 linear accelerator using mcnp4c monte carlo code materials and methods: the head of elekta sl-25 linac was simulated for 6 and 18 mv photon beams using mcnp4c mc code. energy sp...

Journal: :Medical physics 1999
X A Li

The peak scatter factor (PSF) for a photon beam is defined as the ratio of the total dose and the primary dose at the depth of dose maximum. The values of the PSF for photon beams ranging from 60Co to 24 MV are calculated using the EGS4 Monte Carlo technique, to avoid measurement difficulties. The calculation shows that the effect of SSD on PSF for high energy photon beams is not significant fo...

C. Chen, C. Xie, D. Jiang, D. Wang, H. Liu, H.L. Zhao, J. Chen, J. Shen, J. Zhang, X. Wang, Z. Bao, Z. Dai,

Background: This paper aimed to analyze the output constancy of a medical linear accelerator using PTW QUICKCHECKwebline and studied the sensitivity of the PTW QUICKCHECKwebline. Materials and Methods:  The paper statistically analyzed the output doses of 6 MV and 10 MV of photons and 6 MeV, 9 MeV, and 12 MeV of electrons from a medical linear accelerator measured before the daily treatment to ...

2006
Mei Sun Lijun Ma

An inverse planning technique was developed for large-sized prostate cancer patients treatments using 6-MV intensity modulated photon beams. Comparisons of the treatment plans between using 6-MV and 18-MV intensity modulated beams were carried out for a cohort of ten patient cases. The dependence of the plan quality on the beam energies was analyzed for these cases. We found that 6-MV produced ...

2010
James C. L. Chow Runqing Jiang Michael K. K. Leung

Although there are many works on evaluating dose calculations of the anisotropic analytical algorithm (AAA) using various homogeneous and heterogeneous phantoms, related work concerning dosimetry due to tangential photon beam is lacking. In this study, dosimetry predicted by the AAA and collapsed cone convolution (CCC) algorithm was evaluated using the tangential photon beam and phantom geometr...

2013
Melanie Fischbach Roger A Hälg Matthias Hartmann Jürgen Besserer Günther Gruber Uwe Schneider

BACKGROUND For patients with high risk breast cancer and mastectomy, radiotherapy is the treatment of choice to improve survival and local control. Target dose is mainly limited due to skin reactions. The feasibility of using 4 MV beams for chest wall treatment was studied and compared to standard 6 MV bolus radiotherapy. METHODS Post-mastectomy IMRT was planned on an Alderson-phantom using 4...

2015
Fasihah Hanum Yusof Ngie Min Ung Jeannie Hsiu Ding Wong Wei Loong Jong Vannyat Ath Vincent Chee Ee Phua Siew Ping Heng Kwan Hoong Ng Chih-Hsin Tang

This study was carried out to investigate the suitability of using the optically stimulated luminescence dosimeter (OSLD) in measuring surface dose during radiotherapy. The water equivalent depth (WED) of the OSLD was first determined by comparing the surface dose measured using the OSLD with the percentage depth dose at the buildup region measured using a Markus ionization chamber. Surface dos...

2011
Christos Chatzigiannis Georgia Lymperopoulou Panagiotis Sandilos Constantinos Dardoufas Emmanouil Yakoumakis Evaggelos Georgiou Pantelis Karaiskos

External beam radiation therapy (RT) is often offered to breast cancer patients after surgical mastectomy followed by breast reconstruction with silicone implants. In some cases, the RT is administered while the patient is still implanted with a temporary tissue expander including a high-density metallic port, which is expected to affect the planned dose distribution. This work uses Monte Carlo...

Journal: :Medical physics 2013
Alexandre Detappe Panagiotis Tsiamas Wilfred Ngwa Piotr Zygmanski Mike Makrigiorgos Ross Berbeco

PURPOSE The aim of this study is to quantify and to compare the dose enhancement factor from gold nanoparticles (AuNP) to tumor endothelial cells for different concentrations of AuNP, and clinical MV beam configurations. METHODS Tumor endothelial cells are modeled as slabs measuring 10 × 10 × 2 μm. A spherical AuNP is simulated on the surface of the endothelial cell, within the blood vessel. ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید