نتایج جستجو برای: osem

تعداد نتایج: 265  

Journal: :Nihon Hoshasen Gijutsu Gakkai zasshi 2007
Keiichi Matsumoto Keishi Kitamura Keiji Shimizu Kenya Murase

PURPOSE Iterative reconstruction has been successfully used in whole-body PET imaging because of reductions in noise and scanning time. However, there are plural algorithms for image reconstruction such as OSEM, RAMLA and Dynamic RAMLA. Dynamic RAMLA (DRAMA) is an iterative algorithm similar to RAMLA, but the relaxation parameter is controlled in such a way that the propagation of noise from pr...

Journal: :Nuclear Medicine Communications 2013

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2001
G El Fakhri S C Moore P Maksud A Aurengo M F Kijewski

UNLABELLED Dual-isotope imaging can allow simultaneous assessment of brain perfusion using a 99mTc-labeled tracer and neurotransmission using an 123I-labeled tracer. However, the images are affected by scatter, cross talk, attenuation, distance-dependent collimator response (DCR), and partial-volume effect. We determined the accuracy and precision of activity quantitation in simulated normal an...

Journal: :Physics in medicine and biology 2009
N Grotus A J Reader S Stute J C Rosenwald P Giraud I Buvat

(18)F-fluoro-deoxy-glucose ((18)F-FDG) positron emission tomography (PET) is one of the most sensitive and specific imaging modalities for the diagnosis of non-small cell lung cancer. A drawback of PET is that it requires several minutes of acquisition per bed position, which results in images being affected by respiratory blur. Respiratory gating techniques have been developed to deal with res...

2017
E. Grassi F. Fioroni E. Mezzenga D. Finocchiaro M. A. Sarti A. Filice A. Versari M. Iori

The purpose of this study was to investigate the influence of the Ordered Subsets Expectation Maximization (OSEM) reconstruction updates implemented in the 177Lu SPECT/CT imaging processing in molecular radiotherapy. A NEMA IEC Body PhantomTM was used to quantify activity in refillable spheres of five different sizes. Images were obtained with a hybrid dual-head SPECT-CT imaging system (Symbia ...

2006
A. Krol V. R. Kunniyur W. Lee K. R. Gangal I. L. Coman E. D. Lipson D. A. Karczewski F. D. Thomas D. H. Feiglin

We implemented a fully-3D ordered subsets expectation maximization (OSEM) algorithm with compensation of attenuation, distance-dependent blurring (DDB) and sensitivity modeling for SPECT performed with cone-beam collimator (CBC). The experimentally obtained detector response to point sources across FOV was fitted to a twodimensional Gauss function with its width (FWHM) varied linearly with the ...

2015
Alen Suljic Petra Tomse Luka Jensterle Damijan Skrk

BACKGROUND The aim of the study was to explore the influence of various time-of-flight (TOF) and non-TOF reconstruction algorithms on positron emission tomography/computer tomography (PET/CT) image quality. MATERIALS AND METHODS Measurements were performed with a triple line source phantom, consisting of capillaries with internal diameter of ∼ 1 mm and standard Jaszczak phantom. Each of the d...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2005
Pierre-Yves Marie Wassila Djaballah Philippe R Franken Chris Vanhove Marc A Muller Henri Boutley Sylvain Poussier Pierre Olivier Gilles Karcher Alain Bertrand

UNLABELLED Gated SPECT recorded with 16 intervals determines left ventricular (LV) ejection fraction more accurately than does gated SPECT recorded with 8 intervals but produces higher image noise. This study aimed to assess the results from sestamibi and (201)Tl 16-interval gated SPECT when both signal-to-noise ratio and spatial resolution were enhanced with an original method of reconstructio...

2017
Emilio Mezzenga Vincenzo D'Errico Marco D'Arienzo Lidia Strigari Koutla Panagiota Federica Matteucci Stefano Severi Giovanni Paganelli Andrew Fenwick David Bianchini Francesco Marcocci Anna Sarnelli

The purpose of this study is to investigate the optimal reference geometry for gamma camera calibration. Yet another question of interest was to assess the influence of the number of 3D Ordered Subsets Expectation Maximization (3D-OSEM) updates on activity quantification for SPECT imaging with 177Lu. The accuracy of 177Lu activity quantification was assessed both in small and in large objects. ...

Journal: :iranian journal of nuclear medicine 2008
mohsen hajizadeh seyed rasoul zakavi mehdi momen-nejad maryam naji

introduction: ordered subset expectation maximization (osem), is an effective iterative method for spect image reconstruction. the aim of this study is the evaluation of the role of system matrix in osem image reconstruction method using four different physical beam radiation models with three detection configurations. methods: spect was done with an arc of 180 degree in 32 projections after i...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید