نتایج جستجو برای: oximetry
تعداد نتایج: 3912 فیلتر نتایج به سال:
BACKGROUND Several pioneering studies have provided evidence for the introduction of universal pulse oximetry screening for critical congenital heart disease. However, whether the benefits of screening reported in studies from high-income countries would translate with similar success to low-income countries is unknown. We assessed the feasibility and reliability of pulse oximetry plus clinical...
THE EFFECT OF DIFFERENT COLORS NAIL POLISH ON OXYGEN SATURATION MEASURED BY PULSE OXIMETRY IN HEALTHY GIRLS
BACKGROUND The nasal ala is an attractive site for pulse oximetry because of perfusion by branches of the external and internal carotid arteries. We evaluated the accuracy of a novel pulse oximetry sensor custom designed for the nasal ala. METHODS After IRB approval, healthy non-smoking subjects [n=12; aged 28 (23-41) yr; 6M/6F] breathed hypoxic mixtures of fresh gas by a facemask to achieve ...
the emergency severity index (esi) is a five-level triage system that has shown promising reliability and validity. according to esi algorithm, in the presence of danger zone respiratory rate (rr), heart rate (hr) or oxygen (o2) saturation, patients should be up-triaged from esi level 3 to 2 hence, the current study aimed to investigate the value of the measurement of vital signs in predicting ...
OBJECTIVE To compare strategies with and without first-day of life pulse oximetry screening to detect critical congenital heart defects (CCHDs). STUDY DESIGN Population based study including all live born infants in Norway in 2005 and 2006 (n = 116 057). Postductal (foot) arterial oxygen saturation (SpO(2)) was measured in apparently healthy newborns after transferral to the nursery, with SpO...
Congenital heart disease (CHD) is one of the most common birth defects, with an incidence of nine out of every 1,000 live births. The mortality of infants with CHD has decreased over the past 3 decades, but significant morbidity and mortality continue to occur if not diagnosed shortly after birth. Pulse oximetry was recommended as a screening tool to detect critical CHD in 2011 by the American ...
STUDY OBJECTIVES The purpose of this cross-sectional study was to confirm the observation that pulse oximetry tracing correlates with pulsus paradoxus, and is therefore a measure of the severity of air trapping in obstructive airway disease. DESIGN Cross-sectional survey. SETTING The ICU in a tertiary care academic hospital. PATIENTS Twenty-six patients consecutively admitted to the ICU w...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید