نتایج جستجو برای: personal dosimeters

تعداد نتایج: 152287  

Journal: :AMRL-TR. Aerospace Medical Research Laboratories 1966
C R Townsend G A Giarrusso H P Silverman

A portable system for the detection of low concentrations of nitrogen tetroxide (N2 0 4 ), fluorine (F 2 ), and unsymmetrical dimethylhydrazine (UDMH) in air has been developed. The detection system is based upon the change of electrical resistivity of thin metal films when exposed to these gases. Silver metal films coated with appropriate salts proved to be applicable to the detection of all t...

Journal: :Physics in medicine and biology 2002
Greg J Salomons Yong S Park Kim B McAuley L John Schreiner

Polyacrylamide gel (PAG) dosimeters show considerable promise as three-dimensional dosimeters for the verification of complex dose distributions associated with conformal therapy. However, the potential of PAG dosimeters has not yet been borne out in clinical practice and it is apparent that basic investigations of these dosimeters are still required. The polymerization reactions in PAG dosimet...

Journal: :Journal of environmental radioactivity 2003
Fazal-ur Rehman K Jamil M Zakaullah F Abu-Jarad S A Mujahid

There are several methods of measuring radon concentrations but nuclear track detector cylindrical dosimeters are widely employed. In this investigation, the consequence of effective volumes of the dosimeters on the registration of alpha tracks in a CR-39 detector was studied. In a series of experiments an optimum radius for a CR-39-based open cylindrical radon dosimeter was found to be about 3...

Journal: :Respiratory care 2010
Daniel P Steinfort Paul Einsiedel Louis B Irving

BACKGROUND Fluoroscopic guidance may be utilized in some bronchoscopic procedures, including ultrasound-guided bronchoscopy for investigation of peripheral pulmonary lesions. Some authors have suggested this procedure may be performed without fluoroscopy, to minimize risks due to radiation exposure. However, the radiation dose has never been quantified, so the risk remains unknown. OBJECTIVE ...

2006
G. Gambarini D. Brusa M. Carrara G. Castellano M. Mariani M. Valente E. Vanossi

Abstract. Gel dosimeters are integrating dosimeters, that enable dose verification in three dimensions. Optical analysis of gel dosimeters has demonstrated to be an available technique for imaging the absorbed in-phantom dose exposed to radiotherapy beams. The goal is to demonstrate the ability of gel dosimeters to achieve accurately and spatial resolution in dose mapping, also when high dose r...

2009
ANA STOCHIOIU MARIA SAHAGIA ION TUDOR Ana Stochioiu Maria Sahagia Ion Tudor

The paper presents a high sensitivity TLD system, designed for the survey of the environmental radioactivity. It is based on the use of TL detectors type LiF:Mg, Cu, P, commercially known as GR-200A. The dosimeter designed in our Institute, contains 3 detectors, and the measurement value is calculated as the arithmetic mean. A very sensitive, TL Reader, READER ANALYSER RA’94 was chosen and an o...

2003
Wanno Lee Bong Jae Lee Chang Woo Lee

Personal dosimeters based on PIN detectors have been widely used because of their simplicity and real time operation. In this paper, the optimal filter thickness and material designed by the Monte Carlo method is 1.0 mm Al plus 0.2 mm Cu. From the results of radiation characteristic analyses, the developed dosimeter has good performance when it is compared with the other conventional those as d...

2008
Leonardo Peres da Silva Claudia Lúcia de Pinho Maurício Lucía Viviana Canevaro Paulo Sérgio Oliveira

OBJECTIVE: The present study evaluates the dose distribution received by physicians involved in hemodynamic procedures of coronary angiography and coronariography. The influence of some factors such as pulsed or continuous fluoroscopy mode and vein and/or artery access site was investigated. MATERIALS AND METHODS: Measurements have been performed with LiF:Mg,Ti thermoluminescent dosimeters plac...

2013
Juha Koivisto Timo Kiljunen Jan Wolff Mika Kortesniemi

When performing dose measurements on an X-ray device with multiple angles of irradiation, it is necessary to take the angular dependence of metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters into account. The objective of this study was to investigate the angular sensitivity dependence of MOSFET dosimeters in three rotational axes measured free-in-air and in soft-tissue equiv...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید