نتایج جستجو برای: pmu
تعداد نتایج: 744 فیلتر نتایج به سال:
Placement of phasor measurement units (PMUs) in power systems has often been formulated for achieving total network observability. In practice, however, the installation process is not implemented at once, but at several stages, because the number of available PMUs at each time period is restricted due to financial problems. This paper presents a novel integer linear programming framework for o...
Electric power system is a critical infrastructure and loss of its resilience and/or operability can lead to negative consequences for the national economy. Modern power systems based on sophisticated computer and communication technologies are characterized by elevated vulnerability to different types of unauthorized malicious access, i.e. cyber-attacks. Wide area measurement system which is b...
Phasor Measurement Units (PMUs) are in growing attention in recent power systems because of their paramount abilities in state estimation. PMUs are placed in existing power systems where there are already installed conventional measurements, which can be helpful if they are considered in PMU optimal placement. In this paper, a method is proposed for optimal placement of PMUs incorporating conve...
Power grids, throughout the world, are operated as large interconnected networks to ensure reliability of supply in an economic way. The interconnected nature of power network makes it vulnerable and sometimes even a small disturbance in the grid may propagate and result in a blackout. Investigations into major blackouts of the decade in the world have identified inadequate monitoring of the dy...
یکی از مسائل مهم این روزهای سیستم های قدرت بدست آوردن اطلاعات صحیح از جای جای سیستم و همچنین داشتن اطلاعات به روز از جزء جزء آن است. یکی از اندازه گیرهای مهم که امروزه توجه بیشتری به آن شده است واحدهای اندازه گیر فیزوری یا pmu ها می باشند. مسئله تخمین حالت سیستم قدرت در صورتیکه این واحدهای اندازه گیری در جای بهینه خود قرار گیرند بخوبی می تواند نتایج مطلوبی را با توجه به تعداد حداقل آنها بدست ده...
Timely remote activation of frequency response, provided by converter-based generation, can improve the damping very low-frequency (VLF) oscillations. The research presented is based on both power system models and actual data from phasor measurement units (PMU) Irish system. performance active control (APC) investigated, variations in wind speed, droop, time lag resource capacity demonstrate t...
Evaporation is one of the largest water losses from most of the dam lakes in Iran. Estimating the evaporation rate enables us to apply the proper evaporation mitigation technologies. In this study, the feasibility of different evaporation estimation methods was studied to find an optimum method with a fair tradeoff between cost and accuracy. The optimum method may vary depending on the climate....
In this paper it is shown that M class PMU (Phasor Measurement Unit) reference model for phasor estimation recommended by the IEEE Standard C37.118.1 with the Amendment 1 is not compliant with the Standard. The reference filter preserves only the limits for TVE (total vector error), and exceeds FE (frequency error) and RFE (rate of frequency error) limits. As a remedy we propose new filters for...
In this paper, a methodology for designing an optimal monitoring architecture by using a limited number of PMU (Phasor Measurement Units) and a PDC (Phase Data Concentrator) is proposed. The optimal design problem consists in defining the optimal location of both the PMU and the PDC by maximizing the expected value of the trace of the observability gramian of the power system over a large numbe...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید