نتایج جستجو برای: radiochromic film dosimetry

تعداد نتایج: 98518  

2014
Maria F. Chan David Lewis Xiang Yu

PURPOSE To assess the possibility of using a public calibration function for radiochromic film dosimetry in dose QA of highly conformal treatment plans. METHODS EBT3 film calibration strips (3.5 × 20 cm2 from lots A101212 and A011713) were exposed on a Varian Trilogy at a facility to a 10 × 10 cm2 open field at doses of 80, 160, 320 cGy using 6MV photons. Together with a strip of unexposed fi...

Journal: :Medical physics 2005
Alexandra Rink I Alex Vitkin David A Jaffray

A system, consisting of a novel optical fiber-based readout configuration and model-based method, has been developed to test suitability of a certain radiochromic medium for real-time measurements of ionizing radiation dose. Using this system with the radiochromic film allowed dose measurements to be performed during, and immediately after, exposure. The rates of change in OD before, during, an...

2013
Maria F. Chan Qinghui Zhang Jingdong Li Preeti Parhar Karen Schupak Chandra Burman

Purpose: To evaluate the measured dose distributions using radiochromic EBT2 films for small fields in iPlan (BrainLab) commissioning. Methods: Radiochromic EBT2 films were irradiated with 6 MV photons on a Varian Trilogy linac using polystyrene phantoms. The measurements included dose profiles and depth doses for field sizes of 1 × 1, 2 × 2, 3 × 3, 4 × 4, and 10 × 10 cm etc. The dose profile m...

2014
Ahmad Nobah Saad Aldelaijan Slobodan Devic Nada Tomic Jan Seuntjens Mohammad Al‐Shabanah Belal Moftah

In this work we compare doses from imaging procedures performed on today's state-of-the-art integrated imaging systems using a reference radiochromic film dosimetry system. Skin dose and dose profile measurements from different imaging systems were performed using radiochromic films at different anatomical sites on a humanoid RANDO phantom. EBT3 film was used to measure imaging doses from a Tom...

Journal: :Applied sciences 2021

The aim of this study was to develop and apply an evaluation method for assessing the accuracy a novel 3D EPID back-projection algorithm in vivo dosimetry. Dosimetry Check (DC) 5.8 evaluated. A slab phantom homogeneously filled, or with air bone inserts, used fluence reconstruction different squared fields. VMAT plans anatomical sites were delivered on anthropomorphic phantom. Dose distribution...