نتایج جستجو برای: rejection coefficient

تعداد نتایج: 203427  

Journal: :iranian journal of medical sciences 0
s.h. jahadi-hossieni organ transplant rearch center, namazee hospital shiraz university of medical sciences shiraz iran. e. kamali department of immunology school of medicine namazee hospital shiraz university of medical sciences shiraz iran m. samani department of ophthalmology & namazee hospital shiraz university of medical sciences shiraz iran a. katbab department of ophthalmology & namazee hospital shiraz university of medical sciences shiraz iran h. khoshniat department of ophthalmology & namazee hospital shiraz university of medical sciences shiraz iran h. movahhedan department of ophthalmology & namazee hospital shiraz university of medical sciences shiraz iran

background: correlations between bone marrow, heart, kidney, liver, skin and lung transplant rejection or survival with human cytokine gene polymorphisms have been described. there are also reports about the role of cytokines and tumor necrosis factors-alpha (tnf-α) on corneal transplant in animal models. further studies are needed to clarify the role of cytokines in corneal allograft rejection...

2014
Zhou Qianneng Xue Rong Li Hongjuan Lin Jinzhao Li Qi Pang Yu Li Guoquan

By adopting the technique of pre-regulator, a high PSRR and low temperature coefficient piecewise-linear bandgap reference (BGR) is designed for analog and mixed-signal application in this paper. The piecewise-linear BGR with pre-regulator, which is analyzed and simulated in SMIC 0.18μm CMOS process, has simple circuit architecture. Simulation results show that piecewise-linear BGR with pre-reg...

2015
Ken Ueno Tetsuya Asai Yoshihito Amemiya

A low-power CMOS voltage reference was developed using a 0.35 m standard CMOS process technology. The device consists of MOSFET circuits operated in the subthreshold region and uses no resistors. It generates two voltages having opposite temperature coefficients and adds them to produce an output voltage with a near-zero temperature coefficient. The resulting voltage is equal to the extrapolate...

Journal: :JCP 2014
Qianneng Zhou Qi Li Hongjuan Li Jinzhao Lin Yu Pang Guoquan Li Lu Deng

A piecewise-linear bandagp reference (BGR) with high power supply rejection ratio (PSRR) and low temperature coefficient is designed for analogue and mixed signal systems in this paper. By adopting LDO regulator, the designed high PSRR piecewise-linear BGR achieves well performances and has a simple architecture. Simulation results show that the PSRR of the designed piecewise-linear BGR with LD...

2011
Giuseppe De Vita Giuseppe Iannaccone

—— An extreme low power voltage reference generator operating with a supply voltage ranging from 0.9 to 4 V has been implemented in AMS 0.35 μm CMOS process. The maximum supply current measured at the maximum supply voltage and at 80 °C is 70 nA. A temperature coefficient of 10 ppm/°C is achieved by means of a perfect suppression of the temperature dependence of the mobility, the compensation o...

2011
Giuseppe De Vita

An extreme low power voltage reference generator operating with a supply voltage ranging from 0.9 to 4 V has been implemented in AMS 0.35m CMOS process. The maximum supply current measured at the maximum supply voltage and at 80 C is 70 nA. A temperature coefficient of 10 ppm C is achieved as the combined effect of 1) a perfect suppression of the temperature dependence of mobility; 2) the compe...

Background and Objectives: Serum amylase increases and its excretion fraction decreases in patients with renal failure. Excretion fraction can be used as a diagnostic way in individuals with acute renal transplant rejection. In this study, the association between amylase excretion fraction and acute renal transplant rejection, was investigated in pediatrics.   Methods: in this case - control s...

Journal: :Optics letters 1998
D A Boas K K Bizheva A M Siegel

Dynamic low-coherence interferometry was used to measure Brownian motion of submicrometer particles within highly scattering media. Strong rejection of multiply scattered light was obtained by combination of a coherence gate with a confocal microscope, thus allowing particle characterization methods generally reserved for optically dilute materials to be applied to optically concentrated suspen...

Journal: :Optics express 2007
Shijun Xiao Maroof H Khan Hao Shen Minghao Qi

We demonstrate predictable resonance wavelength shifts in silicon micro-resonators by varying their perimeters using high-resolution lithography. The linear coefficient between the resonance wavelength shifts and the perimeter changes is determined with detailed experiments, and found to be nearly constant across the C and L bands in telecommunications. This empirical coefficient is also compar...

2014
Mario C. Deng Barbara Elashoff Michael X. Pham Jeffrey J. Teuteberg Abdallah G. Kfoury Randall C. Starling Thomas P. Cappola Andrew Kao Allen S. Anderson William G. Cotts Gregory A. Ewald David A. Baran Roberta C. Bogaev Khurram Shahzad David Hiller James Yee Hannah A. Valantine

BACKGROUND Gene expression profiling test scores have primarily been used to identify heart transplant recipients who have a low probability of rejection at the time of surveillance testing. We hypothesized that the variability of gene expression profiling test scores within a patient may predict risk of future events of allograft dysfunction or death. METHOD Patients from the IMAGE study wit...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید