نتایج جستجو برای: seismic isolation

تعداد نتایج: 166977  

2008
K Agatsuma R Takahashi K Arai D Tatsumi M Fukushima T Yamazaki M K Fujimoto Y Arase N Nakagawa A Takamori K Tsubono K Kuroda M Ohashi R Desalvo A Bertolini S Márka

A new seismic isolation system, TAMA Seismic Attenuation System (TAMA-SAS), was installed to TAMA300 in order to improve the sensitivity at low frequencies. Inertial damping is one of the hierarchical control systems of the TAMA-SAS which are employed to give full play to its ability. We have established two servo loops to control the Inverted Pendulum (IP) which composes the SAS. One is the se...

2015
Osman E. Ozbulut Stefan Hurlebaus

This study proposes two fuzzy logic controllers (FLCs) for operating control force of piezoelectric friction dampers used for seismic protection of base-isolated buildings against various types of earthquake excitations. The first controller employs a hierarchic control strategy in which a higher-level supervisory controller operates a single sub-level FLC by modifying its input normalization f...

2012
Katsumi Kurita Shigeru Aoki Yuuji Nakanishi Kazutoshi Tominaga Mitsuo Kanazawa

A small base isolation system using a new device that used friction force was developed. In this paper, dynamic characteristics of the system were investigated by an experiment using artificial seismic wave. The bearing combination of three cases, four spherical metal bearings, two spherical metal and two marble plate bearings, four marble plate bearings, was done in the experiment. The peak ac...

2014
Sathish Kumar

Earthquakes are one of the natural hazards that occur due to sudden violent movement of earth’s surface which releases energy and has destructive power in many parts of the world. The development of recent technologies for the control of seismic hazards catches the attention of structural engineers to make the structures seismically resistant. The seismic base isolation technique is a passive p...

2002
J. Giaime B. Lantz C. Hardham R. Adhikari

This technical note outlines the design of an external seismic pre-isolation system proposed for use in LIGO Livingston. The goal is to reduce the effects of the site’s excess ground noise in the 1 3 Hz frequency band, allowing detector noise performance equivalent to that of the 4 km LIGO Hanford detector. The center histogram in Figure 8 shows the most troubling aspect of the excess noise qui...

Journal: :Nuclear Engineering and Technology 2014

Journal: :Journal of Structural and Construction Engineering (Transactions of AIJ) 2014

Journal: :Journal of Sustainable Construction Materials and Technologies 2018

2004
R Abbott R Adhikari G Allen

A seismic isolation system for the proposed 'Advanced LIGO' detector upgrade is under development. It consists of a two-stage in-vacuum active isolation platform that is supported by an external hydraulic actuation stage. A full-scale preliminary-design technology demonstrator of the in-vacuum platform has been assembled and is being tested at Stanford's engineering test facility. Unanticipated...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید