نتایج جستجو برای: shunt active power filter

تعداد نتایج: 1024560  

Journal: :international journal of electrical and electronics engineering 0
e. abirii m.r. salehiii a. abrishamifariii

active filters have proven to be more effective than passive techniques to improve power quality and to solve harmonic and power factor problems due to nonlinear loads. this paper proposes a control scheme based on the instantaneous active and reactive power. the inverter of this active filter is a three-phase, two-level converter. space vector technique is used as modulators and pattern genera...

Journal: :the modares journal of electrical engineering 2010
ali yazdian varjani jo chicharo sarat - perera

this paper presents a new control methodology for active power filters that provide an adaptive online harmonic estimation with partial and selective harmonic reduction schemes, which has been implemented within an integrated controller. the proposed approach is to provide partial and selective reduction of those individual harmonics which exceed the recommended levels as set by regulatory bodi...

2009
Charles S

This paper presents a new Hybrid Filter for compensating voltage/current harmonic in Variable Frequency Drives (VFD). It is a combined system of Shunt Passive Filter (SPF) and a Series Active Filter (SAF) is a cost-effective and practical way of mitigating both current and voltage harmonics generated in a power system due to the presence of non-linear loads. In this paper a practical VFD system...

2014
Vandana Sharma Anurag Singh Tomer

This paper presents an overview of different control methods which are applied on Shunt Active Power Filter to achieve harmonics reduction and power factor improvement. In recent decades, the world has seen an expansion in the use of non-linear loads. These loads draw a non-sinusoidal current from the source and distribute them throughout the system. As a result the power quality degrades. Ther...

2014
S. LEELA

This paper deals with the simulation of a shunt active filter using seven level cascaded H-bridge multilevel inverter. The proposed active filter topology can also produce seven voltage levels, which significantly reduces the switching current ripple and the size of passive components. The seven level active shunt filter provides compensation of load power factor and current harmonics. For comp...

2013
K. Srinivas S. S. Tulasi Ram Gary W. Chang N. M Pawar Vasco Soares Pedro Verdelho

The increasing use of power electronic based loads (adjustable speed drives, switch modern power supplies, etc) to improve system efficiency and controllability is increasing concern for harmonic distortion levels in end use facilities and on overall power system. The Active Power Filter uses power electronic switching to generate harmonic currents that cancel harmonic content from non – linear...

2013

The three-phase Shunt hybrid APF topology for harmonic mitigation in low and medium voltage power distribution systems consists of a VSI based three phase shunt active filter (SAF) and tuned passive filters (TPF) connected in parallel with the load. This chapter discusses the modelling of shunt active filter and design of filter interfacing inductor, DC bus capacitor, tuned passive filters. It ...

2012
N. Senthilnathan T. Manigandan

This paper presents a new and simple control strategy to determine reference compensation currents, under balanced and unbalanced source voltages which using the voltage source inverter for harmonic filtering of a three phase shunt active filter. The proposed control system is able to compensate the harmonics and reactive power of the non linear loads. The proposed approach is compared with a r...

2013
A. M Bouzid

The Self Excited Induction Generator (SEIG) is an isolated power source, whose terminal voltage and frequency are controlled by the excitation of capacitance or the load impedance. A new strategy based on an active power filter (APF) for controlling the current and power quality of the self-excited induction generator (SEIG) is also presented in this paper. The proposed active filter proved to ...

2011
T. Narongrit K - L. Areerak

This paper presents the comparison study of current control techniques for shunt active power filter. The hysteresis current control, the delta modulation control and the carrier-based PWM control are considered in the paper. The synchronous detection method is used to calculate the reference currents for shunt active power filter. The simulation results show that the carrier-based PWM control ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید