نتایج جستجو برای: small diameter implants
تعداد نتایج: 929464 فیلتر نتایج به سال:
The purpose of this prospective clinical study was to investigate the outcome of 3 different types of endosseous, nonsubmerged implants in the anterior part of the mandible. Fourteen older edentulous patients, 10 females and 4 males, were included. All participants received 3 different types of endosseous implants in the anterior mandible: 1 titanium plasma-sprayed cylindric implant (4 mm in di...
We investigated the short-term clinical outcomes of narrow-diameter short-length implants for the fixed-prosthetic partial rehabilitation of extremely resorbed jaws. Twenty-three patients requiring partial rehabilitations with narrow-platform short-length implants in any jaw were included in this study. In total, 30 implants 3.3 mm in diameter and 7 (n = 15 implants) or 8.5 (n = 15 implants) mm...
PURPOSE This retrospective study analyzed the distribution of the dental implants with regards to age and gender of the patients and type of indication for the implant therapy, as well as the location, dimension and type of the implants. MATERIALS AND METHODS The data of demographics (age and gender), type of indication for implant therapy, anatomical location, dimensions (length and diameter...
This study evaluated the stress behavior around short implants in edentulous atrophic mandibles. Six groups included implants with two diameters regular and wide (4 and 5 mm) and three lengths (5, 7 and 9 mm) as follows: Ci9 (9 x 4 mm), Ci7 (7 x 4 mm), Ci5 (5 x 4 mm), Wi9 (9 x 5 mm), Wi7 (7 x 5 mm) and Wi5 (5 x 5 mm). These groups were compared to the control group CG (11 x 4 mm). The analysis ...
Minimally invasive dentistry is a reality that in the last several years has involved all branches of dentistry. In implantology these minimally invasive techniques have revolutionized the standard treatments and are showing a high possibility of increased practice. Some examples applied in implantology include digital radiology, CT reconstructions, and their evolution with maximum reduction of...
Orthodontic management for patients with single or bilateral congenitally missing permanent lateral incisors is a challenge to effective treatment planning. Over the last several decades, dentistry has focused on several treatment modalities for replacement of missing teeth. The two major alternative treatment options are orthodontic space closure or space opening for prosthetic replacements. F...
Orthodontic management for patients with single or bilateral congenitally missing permanent lateral incisors is a challenge to effective treatment planning. Over the last several decades, dentistry has focused on several treatment modalities for replacement of missing teeth. The two major alternative treatment options are orthodontic space closure or space opening for prosthetic replacements. F...
BACKGROUND Implant restorations have become a high predictable treatment option. Several caracteristics such as surgical technique and implant design can influence the treatment outcomes. The aim of the present study was to evaluate the influence of implant macro-design on primary stability measured with resonance frequency analysis (RFA) and insertion torque (IT). Material and Mehods: A total ...
Effect of mini-implant length and diameter on primary stability under loading with two force levels.
Mini-implants are widely utilized as anchorage units in orthodontic treatment. Nevertheless, there are factors that interfere with their clinical performance. The aim of this study was to examine the impact of length and diameter on the primary stability of two different types of orthodontic mini-implants loaded with two force levels. A total of 90 self-drilling mini-implants were inserted in b...
Many inserted implants are affected by peri-implantitis. The aim of our study was to evaluate increases in implant temperature, depending on the diameter and chemical composition of implants. In particular we measured the time it takes for the temperature of an implant to rise by 10°C and evaluated laser power settings required to prevent thermal injury when an implant surface is decontaminated...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید