نتایج جستجو برای: small diameter implants

تعداد نتایج: 929464  

Journal: :The International journal of oral & maxillofacial implants 1999
A K Røynesdal E Ambjørnsen H R Haanaes

The purpose of this prospective clinical study was to investigate the outcome of 3 different types of endosseous, nonsubmerged implants in the anterior part of the mandible. Fourteen older edentulous patients, 10 females and 4 males, were included. All participants received 3 different types of endosseous implants in the anterior mandible: 1 titanium plasma-sprayed cylindric implant (4 mm in di...

Journal: :Journal of oral science 2017
Paulo S Maló Miguel A de Araújo Nobre Armando V Lopes Ana S Ferro

We investigated the short-term clinical outcomes of narrow-diameter short-length implants for the fixed-prosthetic partial rehabilitation of extremely resorbed jaws. Twenty-three patients requiring partial rehabilitations with narrow-platform short-length implants in any jaw were included in this study. In total, 30 implants 3.3 mm in diameter and 7 (n = 15 implants) or 8.5 (n = 15 implants) mm...

2013
Canan Bural Hakan Bilhan Altuğ Çilingir Onur Geçkili

PURPOSE This retrospective study analyzed the distribution of the dental implants with regards to age and gender of the patients and type of indication for the implant therapy, as well as the location, dimension and type of the implants. MATERIALS AND METHODS The data of demographics (age and gender), type of indication for implant therapy, anatomical location, dimensions (length and diameter...

Journal: :Brazilian oral research 2017
Marcele Jardim Pimentel Wander José da Silva Altair Antoninha Del Bel Cury

This study evaluated the stress behavior around short implants in edentulous atrophic mandibles. Six groups included implants with two diameters regular and wide (4 and 5 mm) and three lengths (5, 7 and 9 mm) as follows: Ci9 (9 x 4 mm), Ci7 (7 x 4 mm), Ci5 (5 x 4 mm), Wi9 (9 x 5 mm), Wi7 (7 x 5 mm) and Wi5 (5 x 5 mm). These groups were compared to the control group CG (11 x 4 mm). The analysis ...

2016
Andrea Mascolo

Minimally invasive dentistry is a reality that in the last several years has involved all branches of dentistry. In implantology these minimally invasive techniques have revolutionized the standard treatments and are showing a high possibility of increased practice. Some examples applied in implantology include digital radiology, CT reconstructions, and their evolution with maximum reduction of...

2016

Orthodontic management for patients with single or bilateral congenitally missing permanent lateral incisors is a challenge to effective treatment planning. Over the last several decades, dentistry has focused on several treatment modalities for replacement of missing teeth. The two major alternative treatment options are orthodontic space closure or space opening for prosthetic replacements. F...

2016

Orthodontic management for patients with single or bilateral congenitally missing permanent lateral incisors is a challenge to effective treatment planning. Over the last several decades, dentistry has focused on several treatment modalities for replacement of missing teeth. The two major alternative treatment options are orthodontic space closure or space opening for prosthetic replacements. F...

Journal: :Medicina oral, patologia oral y cirugia bucal 2016
Naroa Lozano-Carrascal Oscar Salomó-Coll Marta Gilabert-Cerdà Nuria Farré-Pagés Jordi Gargallo-Albiol Federico Hernández-Alfaro

BACKGROUND Implant restorations have become a high predictable treatment option. Several caracteristics such as surgical technique and implant design can influence the treatment outcomes. The aim of the present study was to evaluate the influence of implant macro-design on primary stability measured with resonance frequency analysis (RFA) and insertion torque (IT). Material and Mehods: A total ...

Journal: :European journal of orthodontics 2011
Athina Chatzigianni Ludger Keilig Susanne Reimann Theodore Eliades Christoph Bourauel

Mini-implants are widely utilized as anchorage units in orthodontic treatment. Nevertheless, there are factors that interfere with their clinical performance. The aim of this study was to examine the impact of length and diameter on the primary stability of two different types of orthodontic mini-implants loaded with two force levels. A total of 90 self-drilling mini-implants were inserted in b...

Journal: :Biomedizinische Technik. Biomedical engineering 2016
Jacek Matys Ute Botzenhart Tomasz Gedrange Marzena Dominiak

Many inserted implants are affected by peri-implantitis. The aim of our study was to evaluate increases in implant temperature, depending on the diameter and chemical composition of implants. In particular we measured the time it takes for the temperature of an implant to rise by 10°C and evaluated laser power settings required to prevent thermal injury when an implant surface is decontaminated...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید