نتایج جستجو برای: thorax phantom

تعداد نتایج: 24331  

Journal: :iranian journal of medical physics 0
peyman hejazi medical physics dept., semnan university of medical sciences, semnan, iran

introduction in computed tomography (ct) technology, an optimal radiation dose can be achieved via changing radiation parameters such as ma, pitch factor, rotation time and tube voltage (kvp) for diagnostic images. materials and methods in this study, the brain, abdomen, and thorax scaning was performed using toshiba 16-slice scannerand standard aapm and ctdi phantoms. aapm phantom was used for...

Journal: :BMC Nuclear Medicine 2006
Karin Knešaurek Josef Machac

BACKGROUND Positron emission tomography (PET) imaging with fluorine-18 (18F) Fluorodeoxyglucose (FDG) and flow tracer such as Rubidium-82 (82Rb) is an established method for evaluating an ischemic but viable myocardium. However, the high cost of PET imaging restricts its wider clinical use. Therefore, less expensive 18F FDG single photon emission computed tomography (SPECT) imaging has been con...

Journal: :Atom Indonesia 2023

One of the drawbacks Intensity Modulated Radiation Therapy (IMRT) technique is that absorbed dose in healthy tissue relatively high. Proton beam has characteristics can compensate for these drawbacks. The Bragg peak characteristic a proton allows administration high radiation doses to target organ only. Non-Small Cell Lung Cancer (NSCLC) cases are located vicinity many vital organs, so exceed c...

2017
A. Mesbahi R. Naseri

Accuracy in the delivered dose to the patients plays an important and vital role in radiotherapy treatments. This happens because of steep gradient of dose-local control and dose-normal tissue complication probability curves. Dosimetric uncertainty of 3%-4% (one standard deviation) in the delivered dose to the target volume as an acceptable level has been recommended(1-3). In many centers, in v...

2014
Wook Jae Yoo Sang Hun Shin Dayeong Jeon Seunghan Hong Hyeok In Sim Seon Geun Kim Kyoung Won Jang Seunghyun Cho Won Sik Youn Bongsoo Lee

A miniature fiber-optic dosimeter (FOD) system was fabricated using a plastic scintillating fiber, a plastic optical fiber, and a multi-pixel photon counter to measure real-time entrance surface dose (ESD) during radiation diagnosis. Under varying exposure parameters of a digital radiography (DR) system, we measured the scintillating light related to the ESD using the sensing probe of the FOD, ...

Abbas Haghparast Golestan Karami Mahdi Momen Nezhad Peyman Hejazi, Shahrokh Naseri Zahra Hozhabri

Introduction In computed tomography (CT) technology, an optimal radiation dose can be achieved via changing radiation parameters such as mA, pitch factor, rotation time and tube voltage (kVp) for diagnostic images. Materials and Methods In this study, the brain, abdomen, and thorax scaning was performed using Toshiba 16-slice scannerand standard AAPM and CTDI phantoms. AAPM phantom was used for...

2014
Imad Ali Nesreen Alsbou Ozer Algan Terence Herman Salahuddin Ahmad

The purpose of this study was to assess quantitatively elongation of mobile targets in cone-beam CT (CBCT) imaging by measurement and modeling. A mathematical model was derived that predicts the measured lengths of mobile targets and its dependence on target size and motion patterns in CBCT imaging. Three tissue-equivalent targets of differing sizes were inserted in an artificial thorax phantom...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2002
Dan J Kadrmas Paul E Christian

UNLABELLED The lesion detectability performance of 6 PET imaging platforms has been compared using a highly reproducible whole-body phantom and localization receiver operating characteristic (LROC) analysis. METHODS A realistic whole-body phantom consisting of brain, thorax with lungs and liver, and pelvis with bladder was assembled and outfitted with 27 semipermanent (22)Na lesions of variou...

Journal: :Kaku igaku. The Japanese journal of nuclear medicine 1999
Y Narita H Iida

Accuracy and limitation of energy-window based scatter correction techniques have been evaluated for myocardial 201Tl SPECT by means of Monte Carlo simulation. In particular, projection view-dependency of energy distribution of the scattered photons was evaluated. Two geometrical configurations were simulated: namely a homogeneous cylindrical radioactivity located asymmetrically in a homogeneou...

2009
Pietro Mancosu Roberto Sghedoni Valentino Bettinardi Federica Fioroni Mark A. Aquilina Elisa Grassi Ferruccio Fazio Giovanni Borasi Maria C. Gilardi

This study aims at evaluating the dependence of 4D-PET data sorting on the number of phases in which the respiratory cycle can be divided. The issue is to find the best compromise to reduce the conflicting effects induced by increasing the number of phases: lesion motion on each set of images decreases, but on the other hand image noise increases. The IQ NEMA 2001 IEC body phantom was used to s...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید