نتایج جستجو برای: titanium dental implants

تعداد نتایج: 240081  

Journal: :Bio-medical materials and engineering 2009
Michiko Terada Shigeaki Abe Tsukasa Akasaka Motohiro Uo Yoshimasa Kitagawa Fumio Watari

Carbon nanotubes (CNTs) have excellent chemical durability, mechanical strength and electrical properties. Therefore, there is interest in CNTs for not only electrical and mechanical applications, but also biological and medical applications. We coated titanium, a common material for dental implants, with multiwalled carbon nanotubes (MWCNTs). First, titanium was aminated and covered with colla...

2012
Ahmed M. Ballo Omar Omar Wei Xia Anders Palmquist

Pure titanium and titanium alloys are well established standard materials in dental implants because of their favorable combination of mechanical strength, chemical stability, and biocompatibility (Brunette et al., 2001). Integration of titanium implants with the surrounding bone is critical for successful bone regeneration and healing of dental implant. The concept of osseointegration was disc...

2016
Raquel Zita Gomes Andres Paraud Freixas Chang-Hun Han Sohueil Bechara Isaac Tawil

Objective. To evaluate horizontal bone gain and implant survival and complication rates in patients treated with titanium meshes placed simultaneously with dental implants and fixed over them. Methods. Twenty-five patients treated with 40 implants and simultaneous guided bone regeneration with titanium meshes (i-Gen®, MegaGen, Gyeongbuk, Republic of Korea) were selected for inclusion in the pre...

2014
Chiara Gardin Letizia Ferroni Eriberto Bressan José L. Calvo - Guirado Marco Degidi Adriano Piattelli Barbara Zavan

Titanium (Ti) is one of the most widely used biomaterials for manufacturing dental implants. The implant surface properties strongly influence osseointegration. The aim of the present study was to in vitro investigate the characteristics of Ti dental implants in terms of mutagenicity, hemocompatibility, biocompatibility, osteoinductivity and biological safety. The Ames test was used to test the...

2014
Marta S Laranjeira Ângela Carvalho Alejandro Pelaez-Vargas Derek Hansford Maria Pia Ferraz Susana Coimbra Elísio Costa Alice Santos-Silva Maria Helena Fernandes Fernando Jorge Monteiro

Dental ceramic implants have shown superior esthetic behavior and the absence of induced allergic disorders when compared to titanium implants. Zirconia may become a potential candidate to be used as an alternative to titanium dental implants if surface modifications are introduced. In this work, bioactive micropatterned silica coatings were produced on zirconia substrates, using a combined met...

2003
Mitsuo Niinomi

Nb, Ta and Zr are the favorable non-toxic alloying elements for titanium alloys for biomedical applications. Low rigidity titanium alloys composed of non-toxic elements are getting much attention. The advantage of low rigidity titanium alloy for the healing of bone fracture and the remodeling of bone is successfully proved by fracture model made in tibia of rabbit. Ni-free super elastic and sha...

2016
Pietro Mandracci Federico Mussano Paola Rivolo Stefano Carossa

Surface modification of dental implants is a key process in the production of these medical devices, and especially titanium implants used in the dental practice are commonly subjected to surface modification processes before their clinical use. A wide range of treatments, such as sand blasting, acid etching, plasma etching, plasma spray deposition, sputtering deposition and cathodic arc deposi...

Journal: :The Journal of prosthetic dentistry 2015
Fahim Vohra Abdul Aziz Al-Kheraif Siti Mariam Ab Ghani Mohamed Ibrahim Abu Hassan Talal Alnassar Fawad Javed

STATEMENT OF PROBLEM Zirconia implants have been used for oral rehabilitation; however, evidence of their ability to maintain crestal bone and periimplant soft tissue health is not clear. PURPOSE The purpose of this systematic review was to evaluate crestal bone loss (CBL) around zirconia dental implants and clinical periimplant inflammatory parameters. MATERIAL AND METHODS The focus questi...

Journal: :The International journal of oral & maxillofacial implants 2003
Ulrich Meyer Hans-Peter Wiesmann Thomas Fillies Ulrich Joos

PURPOSE The treatment of patients with early or immediately loaded dental implants has renewed interest in the behavior of osteoblasts at the implant surface under load. A newly designed dental implant indicated for immediate loading was tested in vivo for early stages of osteoblast behavior at the implant surface. MATERIALS AND METHODS Thirty-two implants were placed in the mandibles of 8 mi...

Journal: :The International journal of oral & maxillofacial implants 1986
T Albrektsson G Zarb P Worthington A R Eriksson

Criteria for the evaluation of dental implant success are proposed. These criteria are applied in an assessment of the long-term efficacy of currently used dental implants including the subperiosteal implant, the vitreous carbon implant, the blade-vent implant, the single-crystal sapphire implant, the Tübingen implant, the TCP-implant, the TPS-screw, the ITI hollow-cylinder implant, the IMZ den...