نتایج جستجو برای: 3d dosimetry

تعداد نتایج: 196009  

Journal: :Physics in medicine and biology 2017
Chinmay D Darne Fahed Alsanea Daniel G Robertson Narayan Sahoo Sam Beddar

Existing systems for proton beam dosimetry are limited in their ability to provide a complete, accurate, and detailed account of volumetric dose distribution. In this work, we describe the design and development of a portable, fast, and reusable liquid scintillator-based three-dimensional (3D) optical detection system for use in proton therapy. Our long-term goal is to use this system clinicall...

2016
Andrew P Robinson Jill Tipping David M Cullen David Hamilton Richard Brown Alex Flynn Christopher Oldfield Emma Page Emlyn Price Andrew Smith Richard Snee

BACKGROUND Patient-specific absorbed dose calculations for molecular radiotherapy require accurate activity quantification. This is commonly derived from Single-Photon Emission Computed Tomography (SPECT) imaging using a calibration factor relating detected counts to known activity in a phantom insert. METHODS A series of phantom inserts, based on the mathematical models underlying many clini...

2013
B Mijnheer I Olaciregui-Ruiz R Rozendaal J-J Sonke H Spreeuw R Tielenburg M van Herk Antoni van Leeuwenhoek

In this paper the various approaches of EPID-based in vivo IMRT and VMAT dose verification, and their clinical implementation, are described. It will be shown that EPID-based in vivo dosimetry plays an important role in the total chain of verification procedures in a radiotherapy department. EPID-based dosimetry, in combination with in-room imaging, is a fast and accurate tool for 3D in vivo ve...

Journal: :Current oncology 2016
L Jin R Wang S Jiang J Yue T Liu X Dou K Zhu R Feng X Xu D Chen Y Yin

PURPOSE We compared dosimetry and clinical toxicity for 3-dimensional conformal radiotherapy (3D-crt), intensity-modulated radiotherapy (imrt), and RapidArc (Varian Medical Systems, Palo Alto, CA, U.S.A.) in locally advanced pancreatic cancer (lapcc). We hypothesized that the technique with better sparing of organs at risk (oars) and better target dose distributions could lead to decreased clin...

Journal: :Acta oncologica 2014
Eduard Gershkevitsh Csilla Pesznyak Borislava Petrovic Joseph Grezdo Krzysztof Chelminski Maria do Carmo Lopes Joanna Izewska Jacob Van Dyk

BACKGROUND AND PURPOSE One of the newer audit modalities operated by the International Atomic Energy Agency (IAEA) involves audits of treatment planning systems (TPS) in radiotherapy. The main focus of the audit is the dosimetry verification of the delivery of a radiation treatment plan for three-dimensional (3D) conformal radiotherapy using high energy photon beams. The audit has been carried ...

Journal: :iranian journal of radiation research 0
sh. akhlaghpoor dr. sh. akhlaghpoor, novin medical radiation institute, p.o.box: 14665/599, tehran, iran; fax:(98) 218086782 m.h. zahmatkesh h. pourbeigi

background: since 1984 mri gel dosimetry has been introduced as a potential technique for 3d dosimetry. most of the studies have measured r1 (1/t1) or r2 (1/t2) properties of the gel depending on the gel type. we have studied image intensity change in the fricke gel by different mri protocols. materials and methods: gel dosimeters contain 0.4 mm ferrous sulphate, 1 mm nacl, 50 mm h2so4 and 1% b...

Introduction: According to the literature, optical coherence tomography (OCT) can be used measure radiation absorbed dose. This study was carried out to design a computed tomography system for the calculation of absorbed dose and optimization of dose delivery in radiotherapy using gel dosimeters. Material and Methods: An advanced charge-coupled device based OCT system was developed in laborator...

A Mesbahi, Ü Kara M Johari, N Gharehaghaji, R Ghanbarnezhad Farshi

Background: While the benefits of cone-beam computed tomography (CBCT) are well known in maxillofacial imaging, the use of this modality is not risk-free.Objective: The aim of this study was to evaluate the exposure doses received by patients during maxillofacial imaging with CBCT.Methods: Entrance surface dose (ESD) was measured by using thermoluminescent dosimeters (TLDs) attached to the eyes...

2013
K Jordan

This review covers papers from the previous two years not being represented at this conference. Optically stimulated luminescence detectors, diamond detectors and radiochromic film are the major topics. An effort to link these papers to 3D dosimetry is included in this brief report. An overall theme of linear, water equivalent response is seen throughout the topics included.

Alireza Nikoofar Khadijeh Asnaashari Mahbobeh Nazarnejad, Mahdi Sadeghi Seied Rabi Mahdavi

Introduction Dosimetric accuracy is a major issue in the quality assurance (QA) program for treatment planning systems (TPS). An important contribution to this process has been a proper dosimetry method to guarantee the accuracy of delivered dose to the tumor. In brachytherapy (BT) of gynecological (Gyn) cancer it is usual to insert a combination of tandem and ovoid applicators with a complicat...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید