2012
Malgorzata Debowska Bengt Lindholm Jacek Waniewski

The mathematical description of hemodialysis (HD) includes two parts: 1) explanation of the exchange between patient’s blood and dialysate fluid across a semipermeable membrane of the dialyzer, and 2) characterization of the solute removal from the patient. The solute transport across the dialyzer membrane depends on the difference in hydrostatic pressure and solute concentration gradients betw...

Journal: :JNMA; journal of the Nepal Medical Association 2009
P Sultania P S Acharya S K Sharma

INTRODUCTION Inadequate dialysis accounts for the high mortality in patients with end stage renal disease (ESRD). In Nepal, due to various factors including financial and logistic limitations, hemodialysis is mostly performed twice-a-week. This study was undertaken to look at adequacy of dialysis in patients undergoing maintenance hemodialysis in Nepal where the patients profile, in terms of di...

Journal: :The Journal of the Medical Society of New Jersey 1984
S Hingorani S L Watkins

Peritoneal dialysis is the major renal replacement therapy for children with end-stage renal disease, with hemodialysis used for a substantial number of pediatric patients. Reduction of morbidity and mortality is a major goal with the use of these modalities. Adequacy of dialysis and maintenance of peritoneal membrane function are important considerations for children on long term dialysis. Bot...

ژورنال: دانشور پزشکی 2014
افشار, رضا , حیدری سراج, مهران, کریمی, سحر,

Background and Objective: Although uremic pruritus (UP) is one of the most common disabling problems in hemodialysis (HD) patients, its associated factors have remained unknown. The purpose of this study was to evaluate the prevalence and severity of UP in a group of Iranian hemodialysis patients and its associated clinical and laboratory factors. Materials and Methods: This cross-sectional ...

Journal: :Nephrology 2013
Peter G Kerr Nigel D Toussaint

GUIDELINE RECOMMENDATIONS • We recommend that either synthetic or cellulosic membranes be used for symptomatic intra-dialytic hypotension as synthetic membranes offer no benefit over cellulosic membranes (1C). • We recommend that high-flux membranes be used to remove molecules such as beta-2 microglobulin because they have been shown to achieve lower serum levels (1A). • We suggest there are po...

Journal: :Peritoneal dialysis international : journal of the International Society for Peritoneal Dialysis 1999
R Gokal

p eritoneal dialysis has undergone considerable change since it was first used in managing end stage renal disease (ESRD) patients in the early 1960s. Its use then was predominantly as a holding procedure for hemodialysis, and as such, it was used in a very limited number of patients. With the introduction of continuous ambulatory peritoneal dialysis (CAPD) in 1976, the use ofPD has increased d...