نتایج جستجو برای: bio impedance analysis

تعداد نتایج: 2895096  

Copper oxide (CuO) nanostructures are of particular interest because of their interesting properties and promising applications in batteries, super capacitors, solar cells, gas sensors, bio sensors, nano fluids and catalysis. In Recent past, more efforts have been received to design materials with different properties which is dependent on morphology.  In this work cupric oxide nano flakes were...

Journal: :Biomedical microdevices 2008
Poorya Sabounchi Alfredo M Morales Pierre Ponce Luke P Lee Blake A Simmons Rafael V Davalos

We present an on-chip microfluidic sample concentrator and detection triggering system for microparticles based on a combination of insulator-based dielectrophoresis (iDEP) and electrical impedance measurement. This platform operates by first using iDEP to selectively concentrate microparticles of interest based on their electrical and physiological characteristics in a primary fluidic channel;...

2012
Hodong Park Sungpil Cho Lee Hojun Yeom

The biological active points (BAP) are known as low resistance spots or good electro-permeable points, have relativelower electric resistance than the surrounding tissues. In this study, a new method for BAP detection using the bio-impedance measurement system based on the adaptive frequency trackingfilter (AFTF) and the transition event detector is presented

2016
Illapha Cuba Gyllensten Alberto G Bonomi Kevin M Goode Harald Reiter Joerg Habetha Oliver Amft John Gf Cleland

BACKGROUND Heart Failure (HF) is a common reason for hospitalization. Admissions might be prevented by early detection of and intervention for decompensation. Conventionally, changes in weight, a possible measure of fluid accumulation, have been used to detect deterioration. Transthoracic impedance may be a more sensitive and accurate measure of fluid accumulation. OBJECTIVE In this study, we...

2008
Ramaraja P. Ramasamy Zhiyong Ren Matthew M. Mench John M. Regan

Electrochemical impedance spectroscopy (EIS) was used to study the behavior of a microbial fuel cell (MFC) during initial biofilm growth in an acetate-fed, two-chamber MFC system with ferricyanide in the cathode. EIS experiments were performed both on the full cell (between cathode and anode) as well as on individual electrodes. The Nyquist plots of the EIS data were fitted with an equivalent e...

Journal: :Biotechnology and bioengineering 2008
Ramaraja P Ramasamy Zhiyong Ren Matthew M Mench John M Regan

Electrochemical impedance spectroscopy (EIS) was used to study the behavior of a microbial fuel cell (MFC) during initial biofilm growth in an acetate-fed, two-chamber MFC system with ferricyanide in the cathode. EIS experiments were performed both on the full cell (between cathode and anode) as well as on individual electrodes. The Nyquist plots of the EIS data were fitted with an equivalent e...

2016
Lei Ren Qing Jiang Keyun Chen Zhipeng Chen Chengfeng Pan Lelun Jiang

A novel micro-needle array electrode (MAE) fabricated by thermal drawing and coated with Ti/Au film was proposed for bio-signals monitoring. A simple and effective setup was employed to form glassy-state poly (lactic-co-glycolic acid) (PLGA) into a micro-needle array (MA) by the thermal drawing method. The MA was composed of 6 × 6 micro-needles with an average height of about 500 μm. Electrode-...

2017
Ji-Seong Park Chan-Young Park Yu-Seop Kim Hye-Jeong Song Jong-Dae Kim

In this paper, we investigated the electrode structure of the electrical bio-sensor to reduce impedance measurement fluctuation. Five pairs of the same electrodes were formed on the PCB substrate, and a fluidic channel was constructed with a double-sided tape and polycarbonate cover so that all the electrodes had the same reagent distribution. In order to find an electrode structure with little...

2009
A. S. Pandya A. Arimoto Ankur Agarwal Y. Kinouchi

This paper proposes a novel approach for measuring Electrical Impedance Tomography (EIT) of a living tissue in a human body. EIT is a non-invasive technique to measure two or three-dimensional impedance for medical diagnosis involving several diseases. To measure the impedance value electrodes are connected to the skin of the patient and an image of the conductivity or permittivity of living ti...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید