Journal: :DEStech Transactions on Computer Science and Engineering 2017

2014
Peter M. McCowan Daniel W. Rickey Pejman Rowshanfarzad Peter B. Greer William Ansbacher Boyd M. McCurdy

EPID images acquired in cine mode during arc therapy have inaccurate gantry angles recorded in their image headers. In this work, methods were developed to assess the accuracy of the gantry potentiometer for linear accelerators. As well, assessments of the accuracy of other, more accessible, sources of gantry angle information (i.e., treatment log files, analysis of EPID image headers) were inv...

2018
Bin Cai S. Murty Goddu Sridhar Yaddanapudi Douglas Caruthers Jie Wen Camille Noel Sasa Mutic Baozhou Sun

Normalize the response of electronic portal imaging device (EPID) is the first step toward an EPID-based standardization of Linear Accelerator (linac) dosimetry quality assurance. In this study, we described an approach to generate two-dimensional (2D) pixel sensitivity maps (PSM) for EPIDs response normalization utilizing an alternative beam and dark-field (ABDF) image acquisition technique an...

2010
Borislava Petrovic Aleksandra Grzadziel Laza Rutonjski Krzysztof Slosarek

INTRODUCTION Enhanced dynamic wedges (EDW) are known to increase drastically the radiation therapy treatment efficiency. This paper has the aim to compare linear array measurements of EDW with the calculations of treatment planning system (TPS) and the electronic portal imaging device (EPID) for 15 MV photon energy. MATERIALS AND METHODS The range of different field sizes and wedge angles (fo...

2015
Dewayne L. Defoor Luis A. Vazquez‐Quino Panayiotis Mavroidis Nikos Papanikolaou Sotirios Stathakis

In this project, we investigated the use of an electronic portal imaging device (EPID), together with the treatment planning system (TPS) and MLC log files, to determine the delivered doses to the patient and evaluate the agreement between the treatment plan and the delivered dose distribution. The QA analysis results are presented for 15 VMAT patients using the EPID measurements, the ScandiDos...

Journal: :Medical physics 2016
Brian Neal Mahmoud Ahmed Kunal Kathuria Tyler Watkins Krishni Wijesooriya Jeffrey Siebers

PURPOSE To present a clinical case in which real-time intratreatment imaging identified an multileaf collimator (MLC) leaf to be consistently deviating from its programmed and logged position by >1 mm. METHODS An EPID-based exit-fluence dosimetry system designed to prevent gross delivery errors was used to capture cine during treatment images. The author serendipitously visually identified a ...

Journal: :Open Chemistry 2022

Abstract In this study, the feasibility of using electronic portal imaging device (EPID) as an analysing equipment for bolus material was evaluated in terms its dosimetric parameters. Seven superflab samples, 4 samples 0.5 cm (S1–S4) and 3 1 thickness (S5–S7), were analysed compared with tissue equivalent water phantom, which selected reference material. Gamma analysis method used to evaluate d...

2016
Youcef El-Mohri Larry E Antonuk Richard B Choroszucha Yi Wang Qihua Zhao

Beams-eye-view imaging applications such as real-time soft-tissue motion estimation are hindered by the inherently low image contrast of electronic portal imaging devices (EPID) currently available for clinical use. We introduce and characterize a novel EPID design that provides substantially increased detective quantum efficiency (DQE), contrast-to-noise ratio (CNR) and sensitivity without deg...

Journal: :Clinical oncology (Royal College of Radiologists (Great Britain)) 2010
M S Zaghloul A G Mousa E Eldebawy E Attalla H Shafik S Ezzat

AIM To compare the accuracy of radiotherapy set-up using an electronic portal imaging device (EPID) versus megavoltage cone beam computed tomography (MV-CBCT) in paediatric patients. MATERIALS AND METHODS In total, 204 pairs of EPID and MV-CBCT were carried out for 72 patients in the first 3 treatment days and weekly thereafter. RESULTS For the whole group, the mean systematic EPID set-up e...

Journal: :Medical physics 2012
L Vazquez Quino S Stathakis A Gutierrez C Esquivel H Alkhatib N Papanikolaou

PURPOSE A software program (MU-EPID) has been developed to perform patient specific IMRT pre-treatment QA verification using an electronic portal imaging device. METHODS The software converts measured images of intensity modulated beams delivered to an EPID, into fluence maps that can be imported in the treatment planning system. The dose can then be calculated in the patient anatomy and comp...