نتایج جستجو برای: chromium removal efficiency

تعداد نتایج: 539305  

2010
Danutė Kaušpėdienė Eglė Kazlauskienė Aušra Selskienė

Removal of chromium complex dye from aqueous solutions by sorption onto a weakly basic, acrylic matrix anion exchanger Purolite A845 and a strongly basic, polystyrene matrix anion exchanger Purolite A 500P has been investigated under various experimental conditions: the initial dye concentration, pH and temperature. The sorption of chromium complex dye proceeds as a result of miscellaneous inte...

Journal: :international journal of environmental research 0

the effluents of tannery industries are the major source of chromium contamination in thegroundwater. in most of the sub-urban areas ground water is the major source of drinking water. for humanbeing long term exposure to chromium is detrimental. the main objective of this study is to assess thegroundwater contamination and to adopt appropriate methods and to develop suitable techniques either ...

2012

Absorptive characteristics of polyaniline synthesized in mixture of water and acetonitrile in 50/50 volume ratio was studied. Synthesized polyaniline in powder shape is used as an adsorbent to remove toxic hexavalent chromium from aqueous solutions. Experiments were conducted in batch mode with different variables such as agitation time, solution pH and initial concentration of hexavalent chrom...

Journal: :health scope 0
hooshyar hossini department of environmental health, faculty of medical sciences, tarbiat modares university, tehran, ir iran abbas rezaee department of environmental health, faculty of medical sciences, tarbiat modares university, tehran, ir iran; department of environmental health, faculty of medical sciences, tarbiat modares university, tehran, ir iran. tel: +98-2182883575, fax: +98-2182883575 golamreza mohamadiyan department of environmental health, faculty of medical sciences, tarbiat modares university, tehran, ir iran

background chromium is one of the most commonly used heavy metals in industry. it is known as a pollutant that its discharge into the environment needs special care. objectives the current study aimed to evaluate the functionalized multi-walled carbon nanotubes (f-mwcnts) as a novel adsorbent of chromium in aqueous solutions. materials and methods the virgin mwcnt was protonated using sulfuric ...

2003
M. D. Brewster J. Passmore

This paper utilizes data from two pilot studies conducted at Superfund Sites to discuss the electrochemical iron addition process developed by Andco Environmental Processes, Inc. Electrical current and steel electrodes were used to put ferrous and hydroxyl ions into solution. Once added, the chemistry was properly manipulated to provide coprecipitation and adsorption conditions capable of simul...

2015
AlkA TRIpATHI ANjANI kUMAR DWIVEDI

Chromium (Cr) is the most important element used to leather industry is still considered to be the most important industries which pollute the environment by chromium metal. Removal of heavy metals dissolved at low concentrations in water and wastewaters is often a problem that can be solved in different ways. This paper describes a study conducted to determine the recovery of chromium from tan...

2012
Debabrata Bera Parimal Chattopadhyay Lalitagauri Ray

The activated sludge has been acclimatized with chromium (VI) ions from 5 mg/L to 20 mg/L. It is observed that the chromium removal percentage, COD removal and mixed liquor suspended solid (MLSS) decrease with the increase in dilution rate. Maximum food to microorganisms ratio (F/M) is found to be 0.19. When initial metal ion concentration increases from 5 mg/L to 20 mg/L, the chromium removal ...

Journal: :Bioresource technology 2006
Vikrant Sarin K K Pant

Several low cost biomaterials such as baggase, charred rice husk, activated charcoal and eucalyptus bark (EB) were tested for removal of chromium. All the experiments were carried out in batch process with laboratory prepared samples and wastewater obtained from metal finishing section of auto ancillary unit. The adsorbent, which had highest chromium(VI) removal was EB. Influences of chromium c...

2016
Ismat H. Ali H. A. Alrafai

BACKGROUND Kinetics, thermodynamics and equilibrium of the removal of chromium(VI) ions from aqueous solutions by using chemically activated leaves of Ficus nitida were investigated. Adsorption runs were performed as a function of pH, mass of biosorbent, contact time, initial concentration of chromium(VI) ions and temperature. RESULTS The optimum conditions for maximum removal of chromium(VI)...

2009
S. Hosseini

The removal of the chromium (VI) ion from aqueous solutions with the Lewatit FO36 ion-exchange resin is described at different conditions. The effects of adsorbent dose, initial metal concentration, contact time and pH on the removal of chromium (VI) were investigated. The batch ion exchange process was relatively fast and it reached equilibrium after about 90 min of contact. The ion exchange p...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید