نتایج جستجو برای: cmrr

تعداد نتایج: 171  

2014
A. Baishya Trupa Sarkar P. P. Sahu M. K. Naskar

This paper presents the design and performance comparison of a two stage operational amplifier topology using CMOS and BiCMOS technology. This conventional op amp circuit was designed by using RF model of BSIM3V3 in 0.6 μm CMOS technology and 0.35 μm BiCMOS technology. Both the op amp circuits were designed and simulated, analyzed and performance parameters are compared. The performance paramet...

2004
Mohammed Ismail Valery N. Ivanov

The design of a new single stage class AB operational amplifier is presented. Amplifier incorporates an input differential pair with minimum current selector and common-mode feedback to control the tail current. It shows small-signal behavior of a simple OTA, while class AB feedback provides high slew rate when large input signals are applied. Prototype circuit was manufactured in 2pm analog CM...

2011
Shashank Dubey Pramod Kumar Jain

This paper describes an instrumentation amplifier (INA) with three operational amplifier (op amp) topology, for biomedical applications. To achieve low offset new circuit technique is achieved by adding NMOS transistor and two phase clock scheme with a frequency of 20 KHz. With the unity gain bandwidth of 92 KHz , the open loop gain of this instrumentation amplifier is found to be 50 dB and hav...

2012
Hamdi ERCAN Sezai Alper TEKİN Mustafa ALÇI

A new approach to the design of an instrumentation amplifier using only 2 CMOS current-controlled conveyors and an active resistor is introduced. The new approach, which has no passive components, offers a wide bandwidth and a high common-mode rejection ratio (CMRR). Electronically controllable gain by voltage and current is also obtained by this new circuit. The circuit is simulated using the ...

2014
K. Rajavardhan Reddy Rama Krishna

In this paper we design the low-power CMOS limiting amplifier using negative impedance, the purpose of using negative impedance is to increase the gain of the amplifier. low-power operations are also done using all the active elements. The LA was implemented in a standard CMOS 0.18um technology. This limiting amplifier is designed for the instrumentation(bio-medical) application. Gain of the am...

2010
Anil Kumar Sharma

In this paper the current mode approach called “Current Conveyor (CCII+)” has been incorporated to design and simulate the circuit for producing two amplitude matched anti-phase sine waveforms which are frequently used in various communication and instrumentation systems. PSpice simulation has been used to depict the output waveforms. The power supply used is ±2.5 V which can be easily incorpor...

2003
Christian Falconi Marco Faccio Arnaldo D'Amico Corrado Di Natale

In low voltage low power CMOS systems both the high input offset and noise voltages of MOSFETs and also the moderate gain of op amps limit the accuracy of analog circuits. In this paper we present a new high-accuracy instrumentation amplifier; this circuit topology is the first ever reported "non-autozero" instrumentation amplifier which allows to compensate, beside the input offset and noise v...

2009
M. J. Nissi L. J. Lehto C. A. Corum D. Idiyatullin O. H. Gröhn M. T. Nieminen

M. J. Nissi, L. J. Lehto, C. A. Corum, D. Idiyatullin, O. H. Gröhn, and M. T. Nieminen Department of Physics, University of Kuopio, Kuopio, Finland, Department of Clinical Radiology, Kuopio University Hospital, Kuopio, Finland, Department of Biotechnology and Molecular Medicine, University of Kuopio, Kuopio, Finland, CMRR, University of Minnesota, Minneapolis, MN, United States, Department of N...

2017
Zhaowen Liu Edmund T. Rolls Jie Zhang Ming Yang Jingnan Du Weikang Gong Wei Cheng He Wang Kamil Ugurbil Jianfeng Feng

1. School of Computer Science and Technology, Xidian University, Xi’an710071, Shannxi, PR China 2. Institute of Science and Technology for Brain Inspired Intelligence, Fudan University, Shanghai, PR China 3. Department of Computer Science, University of Warwick, Coventry CV4 7AL, UK 4. Oxford Centre for Computational Neuroscience, Oxford UK 5. Center for Magnetic Resonance Research (CMRR), Univ...

پایان نامه :وزارت علوم، تحقیقات و فناوری - موسسه آموزش عالی غیرانتفاعی و غیردولتی سجاد مشهد - دانشکده مهندسی برق و الکترونیک 1392

در بیوآمپلی¬فایرها سیگنال بیولوژیکی دریافتی دامنه بسیار ضعیفی دارد و ولتاژ آفست ناشی از ورودی¬ها و همچنین ناشی از الکترودها به مراتب از دامنه بیوسیگنال بیشتر است. این ولتاژ آفست در مدار ایجاد مشکل می کند، اگر بهره طبقه اول تقویت کننده را بالا در نظر بگیریم این ولتاژ آفست سبب به اشباع رفتن تقویت کننده می-شود لذا نیاز داریم تا ولتاژ آفست را به نوعی حذف کنیم. ضریب حذف مود مشترک زیاد یکی از عوامل م...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید