نتایج جستجو برای: collimator detector response

تعداد نتایج: 1033857  

Journal: :Physics in medicine and biology 1994
Z Liang J Ye D P Harrington

An analytical approach to quantitative brain SPECT (single-photon-emission computed tomography) with non-uniform attenuation is developed. The approach formulates accurately the projection-transform equation as a summation of primary- and scatter-photon contributions. The scatter contribution can be estimated using the multiple-energy-window samples and removed from the primary-energy-window da...

Journal: :Physics in medicine and biology 2004
Gengsheng L Zheng Daniel Gagnon

In this paper, we propose a CdZnTe rotating and spinning gamma camera attached with a slit collimator. This imaging system acquires convergent planar integrals of a radioactive distribution. Two analytical image reconstruction algorithms are proposed. Preliminary phantom studies show that our small CdZnTe camera with a slit collimator outperforms a larger NaI(Tl) camera with a pinhole collimato...

ژورنال: سنجش و ایمنی پرتو 2020

Radiation detection is essential for determining of radiation dose. Depend on the detector and dosimetry method, detection process is performed in different levels. Pulse counting is the first level of detection. Typically, the output of a radiation detector for determining value of the radiation dose cannot be used directly. Through changing the response function or the readout detector, is tr...

Journal: :Nuclear Instruments and Methods in Physics Research 2021

Gamma-ray spectrometry is widely applied in several science fields, and particular non-destructive gamma scanning emission tomography of irradiated nuclear fuel. Often, a collimator used the experimental setup, to selectively interrogate region interest For optimization instrument design, as well for planning measurement campaigns, predictive models transmitted gamma-ray intensity through are n...

Journal: :Physics in medicine and biology 2015
Patricia Cambraia Lopes Enrico Clementel Paulo Crespo Sebastien Henrotin Jan Huizenga Guillaume Janssens Katia Parodi Damien Prieels Frauke Roellinghoff Julien Smeets Frederic Stichelbaut Dennis R Schaart

Proton range monitoring may facilitate online adaptive proton therapy and improve treatment outcomes. Imaging of proton-induced prompt gamma (PG) rays using a knife-edge slit collimator is currently under investigation as a potential tool for real-time proton range monitoring. A major challenge in collimated PG imaging is the suppression of neutron-induced background counts. In this work, we pr...

2015
S. Barros I. Bergström

In 2014 a new vertical flight path was installed at the neutron time-of-flight facility, n TOF, at CERN. The beam line optimization of this second experimental area (EAR2) was performed by FLUKA simulations with a detailed model of the facility, including the spallation target, neutron beam line, magnet, collimators and beam dump. The beam profile as well as neutron and gamma fluxes were calcul...

Journal: :Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics 2016
Mayuresh Kulkarni Ronald Dendere Fred Nicolls Stef Steiner Tania S Douglas

We present a method for simulating slot-scanning X-ray imaging using the general-purpose Monte Carlo simulation package PENELOPE and penEasy Imaging. Different phantoms can be defined with the PENGEOM package, which defines bodies as combinations of volumes limited by quadric surfaces. The source-detector geometry, the position of the object, the collimator, the X-ray tube properties, the detec...

Journal: :Medical physics 2015
Yanfei Mao Zhicong Yu Gengsheng L Zeng

PURPOSE This work is a preliminary study of a stationary cardiac SPECT system. The goal of this research is to propose a stationary cardiac SPECT system using segmented slant-hole collimators and to perform computer simulations to test the feasibility. Compared to the rotational SPECT, a stationary system has a benefit of acquiring temporally consistent projections. The most challenging issue i...

Journal: :Medical physics 2006
J H Siewerdsen M J Daly B Bakhtiar D J Moseley S Richard H Keller D A Jaffray

X-ray scatter poses a significant limitation to image quality in cone-beam CT (CBCT), resulting in contrast reduction, image artifacts, and lack of CT number accuracy. We report the performance of a simple scatter correction method in which scatter fluence is estimated directly in each projection from pixel values near the edge of the detector behind the collimator leaves. The algorithm operate...

Journal: :Physics in medicine and biology 2013
Xiao Deng Jean-François Beaudoin Jules Cadorette Charles Naaman Roger Lecomte Rutao Yao

We developed SPECT imaging capability on an animal PET scanner to provide a cost effective option for animal SPECT imaging. The SPECT add-on sub-system was enabled by mechanically integrating a multiple-pinhole collimator in the PET detector ring. This study introduces a method to calibrate the geometrical parameters of the SPECT add-on using the PET imaging capability of the scanner. The propo...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید