نتایج جستجو برای: current transformer

تعداد نتایج: 786794  

2015
J. Doggett J. Gahl K. Zinsmeyer

A current probe has been designed which allows measurement of ns;pulsed currents in high voltage environments. The probe consists of a current transformer and an optical transducer. The transformer coil in a metallic torus is considered as a slow-wave transmission line and is terminated with its wave impedance. In this mode of operation current pulses shorter than twice the transit time of the ...

2015
H. Balaga D. N. Vishwakarma H. Nath

This paper presents the use of Artificial Neural Networks (ANN) as a pattern classifier for the combined differential protection of generator-transformer unit with an aim to build a backup protection system to improve the overall reliability of the system. The proposed neural network model is trained and tested with an efficient Resilient Back propagation (RPROP) algorithm and Genetic Algorithm...

2007
M. E. HAMEDANI GOLSHAN

In this paper, a new algorithm based on processing differential current harmonics is proposed for digital differential protection of power transformers. This algorithm has been developed by considering different behaviors of second harmonic components of the differential currents under fault and inrush current conditions. In the new method, a criterion function is defined in terms of the time v...

2017
Jingang Wang Diancheng Si Tian Tian Ran Ren

An electronic current transformer with a B-dot sensor is proposed in this study. The B-dot sensor can realize the current measurement of the transmission line in a non-contact way in accordance with the principle of magnetic field coupling. The multiple electrodes series-opposing structure is applied together with differential input structures and active integrating circuits, which can allow th...

2006
S. AL Ahmadi

Power system protective relaying systems are striving to meet the demands of systems which are ever increasing in complexity. . High-speed digital relays must make decisions while the power system is still in transition. Understanding the operation and performance of microprocessor based relays requires new engineering tools. Current transformer (CT) and relay modeling are practical tools to ev...

Journal: :مهندسی قدرت ایران 0
reza shariatinasab university of birjand, iran z ejtemaee university of birjand, iran j gholinezhad university of birjand, iran

power system overvoltages due to switching, lightning and other disturbances are the main problem for designers of the power transformers. once some frequencies of the incoming surges match with some of the natural frequencies of transformer winding, the resonance phenomenon is expected in transformer winding. the resonant overvoltages may destroy the insulation between turns and cause to insul...

Transformer insulating oil nanofluid is made to improve dielectric and thermal properties of the oil by employing nanoparticles with proper properties. In the current work, nanofluids based on transformer mineral oil were prepared by three procedures using diamond nanoparticles with high thermal conductivity, as well as high dielectric properties. It was tried to consider the impacts of surfact...

2013
Neelam Choudhary Ranjana Nigam Singh

Magnetic core saturation of transformers and rotating machines generate harmonics. Harmonics are integer multiples of the fundamental frequency. Harmonics is caused by nonlinear devices in the power system. Due to the non-linear loads, power frequency harmonics exist mainly in distribution systems. The current harmonics cause voltage harmonics, hence resulting in nonsinusoidal supply voltage in...

2010
Chairul Gagarin Irianto Rudy Setiabudy Chairul Hudaya

The delta primary transposed zigzag secondary (DTz) transformer has been designed and used to reduce the bad impacts of the harmonic in the distribution power system. The DTz transformer is constructed with delta connection in primary winding and the three transposed windings at the different core legs of secondary winding. The harmonic reduction method of the DTz transformer applies two basic ...

Journal: :IEEE Trans. Education 2001
Kenneth V. Cartwright

The power supply analysis and design results of Sherman and Hamacher are extended to include approximate solutions to the nonlinear equations that define the rectifier turn-on angles. Additionally, peak rectifier current solely as a function of ripple factor, as well as the inverse relationship, i.e., ripple factor as a function of peak rectifier current, are also provided. Simplified exact equ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید