نتایج جستجو برای: dynamic condylar screw

تعداد نتایج: 423391  

2017
Johnny Paulsson Josefine Corin Stig Ola Olsson

BACKGROUND In treatment of unstable trochanteric fractures dynamic hip screw and Medoff sliding plate devices are designed to allow secondary fracture impaction, whereas intramedullary nails aim to maintain fracture alignment. Different treatment protocols are used by two similar Swedish regional emergency care hospitals. Dynamic hip screw is used for fractures considered as stable within the r...

بهادر اعلمی هرندی, , مجید سجادی ساروی, , محمدنقی طهماسبی, ,

Cut out or extrusion of the lag screw from the superior aspect of head and neck of the femur is one of the most common and devastating complications of the surgery of the intertrochanteric fractures with DHS. The exact cause of this complications is unknown, but it seems to be related to osteopenia, inappropriate position of lag screw inside head of the femur and inability of DHS to slide insid...

2009
Ching-Chi Hsu Jinn Lin Yongyut Amaritsakul Takalamesar Antonius Ching-Kong Chao

Dynamic hip screw and gamma nail have been widely used to treat the patients with proximal femoral fractures, but clinical failures of those implants are still to be found. This study developed three-dimensional finite element models to investigate the biomechanical performances of the implants. Two kinds of commercially available implants (dynamic hip screw and gamma nail) and one newly design...

Journal: :Orthopedics 2012
Zhiping Zhou Xingxiang Zhang Shoujin Tian Yaogang Wu

The purpose of this study was to compare minimally invasive and conventional dynamic hip screw techniques for the treatment of intertrochanteric fractures in older patients. Relevant randomized, controlled studies were included. The methodological quality was assessed, and data were extracted independently. Five studies (353 fractures) that compared minimally invasive and conventional dynamic h...

Journal: :Chinese medical journal 2015
Yun-Gang Luo Tao Yu Guo-Min Liu Nan Yang

BACKGROUND We aimed to use the animal model of dynamic fixation to examine the interaction of the pedicle screw surface with surrounding bone, and determine whether pedicle screws achieve good mechanical stability in the vertebrae. METHODS Twenty-four goats aged 2-3 years had Cosmic ® pedicle screws implanted into both sides of the L2-L5 pedicles. Twelve goats in the bilateral dynamic fixatio...

2015
Saeed Asiri Hamza Diken

Many of the papers studying the screw-drive system dynamic model concentrated on the control methodologies that is why vibrational models are either simple lumped models or simplified flexible beam models. In this paper a screw-drive system dynamic model and its vibrations are discussed. The screw is considered as an EulerBernoulli type flexible beam with fixed-free boundary conditions and the ...

2015
Herminio García-Roncero Jordi Caballé-Serrano Jordi Cano-Batalla Josep Cabratosa-Termes Oscar Figueras-Álvarez

PURPOSE In this study, a temporal abutment fixation screw, designed to fracture in a controlled way upon application of an occlusal force sufficient to produce critical micromotion was developed. The purpose of the screw was to protect the osseointegration of immediate loaded single implants. MATERIALS AND METHODS Seven different screw prototypes were examined by fixing titanium abutments to ...

2017
Jesse Chieh-Szu Yang Hsin-Chang Chen Yu-Shu Lai Cheng-Kung Cheng

Fixation with a dynamic hip screw (DHS) is one of the most common methods for stabilizing intertrochanteric fractures, except for unstable and reverse oblique fracture types. However, failure is often observed in osteoporotic patients whereby the lag screw effectively 'cuts out' through the weak bone. Novel anti-migration blades have been developed to be used in combination with a lag screw ('B...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید