نتایج جستجو برای: electron therapy magnetic field practical range lateral deflection dose distribution

تعداد نتایج: 3424787  

Journal: :Medical physics 2012
I Ciancaglioni Marco Marinelli E Milani G Prestopino C Verona G Verona-Rinati R Consorti A Petrucci F De Notaristefani

PURPOSE To determine the potentialities of synthetic single crystal diamond Schottky diodes for accurate dose measurements in radiation therapy small photon beams. METHODS The dosimetric properties of a diamond-based detector were assessed by comparison with a reference microionization chamber. The diamond device was operated at zero bias voltage under irradiation with high-energy radiotherap...

Journal: :iranian journal of medical physics 0
seyed mostafa ghavami department of radiology, paramedical school, tabriz university of medical sciences, tabriz, iran hosein ghiasi medical radiation sciences research team, tabriz university of medical sciences tabriz, iran

introduction accurate estimation of the skin-absorbed dose in external radiation therapy is essential to estimating the probability of secondary carcinogenesis induction materials and methods electron contamination in prostate radiotherapy was investigated using the monte carlo (mc) code calculation. in addition, field size dependence of the skin dose was assessed. excess cancer risk induced by...

Journal: :Physics in medicine and biology 2000
U Weber W Becher G Kraft

Only target-conformal treatment allows one to exploit the advantages of ion beams (the increased dose and high biological efficiency at the end of the particle range) to a maximum extent. Up to now, target-conformal treatments such as spot scanning or intensity-controlled raster scanning have used fast magnetic lateral deflection in one or two directions perpendicular to the beam axis and a slo...

Journal: :Nano letters 2015
Kangmook Lim Chad Ropp Benjamin Shapiro Jacob M Taylor Edo Waks

Nitrogen vacancy (NV) color centers in diamond enable local magnetic field sensing with high sensitivity by optical detection of electron spin resonance (ESR). The integration of this capability with microfluidic technology has a broad range of applications in chemical and biological sensing. We demonstrate a method to perform localized magnetometry in a microfluidic device with a 48 nm spatial...

Journal: :iranian journal of radiation research 0
s.b. jia department of physics , ferdowsi university of mashhad, mashhad, iran a.a. mowlavi department of physics , hakim sabzevari university, sabzevar, iran m.h. hadizadeh department of physics , ferdowsi university of mashhad, mashhad, iran m. ebrahimi loushab department of physics , ferdowsi university of mashhad, mashhad, iran

background: the advantages of proton beam in radiation therapy- like small lateral scattering as well as absence of exit dose tail in the organs which are after the tumor- make it capable of delivering more treatment doses to the target and much lesser to the critical tissues near it. materials and methods: in this study, the monte carlo mcnpx code has been used to simulate a slab head phantom ...

ژورنال: سنجش و ایمنی پرتو 2014

In this paper, graphite calorimeter device which is using to calibrate the electron beam of therapy accelerators in the range of the low dose was simulated using the EGS4 calculation code. Then, the electron beam dose distributions were calculated in it and the effects of parameters such as thickness of the calorimeter core, the distance to the source, thickness of air gap around the core, thic...

2014
Taeho Roy Kim Ai Leen Koh Robert Sinclair

The study of magnetic materials requires an understanding of not only their magnetic properties, but also their microstructure. Transmission electron microscopy (TEM) is a powerful characterization instrument because of its ability to provide both microstructural and magnetic information. In TEM, electrons can be deflected by a Lorentz force created by a magnetic field from a magnetic material....

Journal: :jentashapir journal of health research 0
mohammad javad tahmasebi birgani department of medical physics, school of medicine, ahvaz jundishapur university of medical sciences, ahvaz, ir iran; department of clinical oncology, golestan hospital, ahvaz jundishapur university of medical sciences, ahvaz, ir iran mansour zabihzadeh department of medical physics, school of medicine, ahvaz jundishapur university of medical sciences, ahvaz, ir iran; department of clinical oncology, golestan hospital, ahvaz jundishapur university of medical sciences, ahvaz, ir iran; student research committee, ahvaz jundishapur university of medical sciences, ahvaz, ir lran; department of medical physics, school of medicine, ahvaz jundishapur university of medical sciences, ahvaz, ir iran. tel: +98-9125032283 sholeh arvandi department of clinical oncology, golestan hospital, ahvaz jundishapur university of medical sciences, ahvaz, ir iran elahe gharibreza department of medical physics, school of medicine, ahvaz jundishapur university of medical sciences, ahvaz, ir iran

conclusions using the maximum dose depth from pdd curves and the inverse square law, the required ssdeff to calculate the dose distribution of the electron beam can be calculated. objectives the aim of this study was to determine the effective source-surface distance (ssdeff) of an electron linear accelerator (linac), and its dependence on energy and depth. materials and methods a varian linac ...

اربابی, عظیم, بلوری, بهرام, ندایی, حسن, قهرمان اصل, روح اله,

  Background & Aim: Nowadays, radiosensitive polymer gels are used as a reliable dosimetry tool for verification of 3D dose distributions. Polymer gel dosimeters consist of an aqueous mixture of monomers and a gelling agent, which after irradiation, 3D dose distribution is acquired by using imaging techniques. The aim of this study is to evaluate the application and capability of normoxic polym...

2014
Hiroshi Kimura Ingrid Mann

The deflection of interstellar dust grains in the magnetic field near the heliopause depends on their surface electric charge. We study the electric charging of the grains with emphasis on the secondary electron emission because of its importance in the hot plasma environment near the heliopause. We correct previous models of the secondary electron emission that overestimate the electric charge...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید