نتایج جستجو برای: epid

تعداد نتایج: 673  

2010
Stephanie Vanterpool Randall Coombs Karamarie Fecho

BACKGROUND This study retrospectively compared the continuous epidural infusion of morphine with a single epidural injection of extended-release morphine for postoperative pain control after arthroplasty. METHODS Medical records were reviewed for subjects who had total knee or hip arthroplasty (THA) under spinal anesthesia and received either a continuous epidural infusion of morphine (Group ...

2010
Savino Cilla Andrea Fidanzio Francesca Greco Domenico Sabatino Aniello Russo Laura Gargiulo Luigi Azario Angelo Piermattei

In-vivo dosimetry techniques are currently being applied only by a few Centers because they require time-consuming implementation measurements, and workload for detector positioning and data analysis. The transit in-vivo dosimetry performed by the electronic portal imaging device (EPID) avoids the problem of solid-state detector positioning on the patient. Moreover, the dosimetric characterizat...

2013
Ngie Min Ung Leonard Wee Sara Lyons Hackett Andrew Jones Tee Sin Lim Christopher Stirling Harper

This study evaluated the agreement of fiducial marker localization between two modalities--an electronic portal imaging device (EPID) and cone-beam computed tomography (CBCT)--using a low-dose, half-rotation scanning protocol. Twenty-five prostate cancer patients with implanted fiducial markers were enrolled. Before each daily treatment, EPID and half-rotation CBCT images were acquired. Transla...

Journal: :Journal of animal science 1990
E J Eisen M T Coffey

Correlated responses in whole-body composition were determined in 12-wk-old male mice from replicate lines selected for 12 generations for high (HF) or low (LF) epididymal fat pad weight as a percentage of body weight (EPID) and high (HL) or low (LL) hind carcass weight as a percentage of body weight. The HF and LF lines diverged (P less than .01) in body fat percentage (FAT) and subcutaneous d...

2012
Daniel W. Bailey Lalith Kumaraswamy Mohammad Bakhtiari Harish K. Malhotra Matthew B. Podgorsak

This study compares the EPID dosimetry algorithms of two commercial systems for pretreatment QA, and analyzes dosimetric measurements made with each system alongside the results obtained with a standard diode array. 126 IMRT fields are examined with both EPID dosimetry systems (EPIDose by Sun Nuclear Corporation, Melbourne FL, and Portal Dosimetry by Varian Medical Systems, Palo Alto CA) and th...

E. Bezak, M. Mohammadi,

ABSTRACT Background: for treatment verification in radiation therapy. Several physical characteristics of ScanningLiquid filled Ionization Chamber EPID (SLIC-EPID) including: extra build-up layer,reproducibility and uniformity, and noise level were investigated.Electronic Portal Imaging Devices (EPIDs) have found an outstanding positionMaterials and Methods: equilibrium, 1-30 mm white water mat...

E. Bezak, M. Mohammadi,

 ABSTRACTBackground: Although Electronic Portal imaging Devices (EPIDs) have originally developed for positioning verification, they can also be used for dosimetric purposes. In the current work, the dose response of minimum detectable thickness of a Scanning Liquid filled Ion Chamber EPID, SLIC-EPID, and the variation of transmitted dose with the shift of inhomogeneity inside of phantom was al...

2016
Bin Liang Bo Liu Fugen Zhou Fang-fang Yin Qiuwen Wu

BACKGROUND In volumetric modulated arc therapy (VMAT), gantry angles, dose rate and the MLC positions vary with the radiation delivery. The quality assurance (QA) system should be able to catch the planning and machine errors. The aim of this study was to investigate the sensitivity of three VMAT QA systems to machine errors. METHODS Several types of potential linac machine errors unique to V...

Farzaneh Allaveisi Nasrin Amini

Introduction: Electronic portal imaging devices (EPIDs) are fundamentally used for instantaneous verification of the patient set‐up, block shape, and leaf positions during radiation therapy. In radiotherapy, situations arise in which an inclined PTV must be treated mutually with adjacent nodal regions. This methodology is most widely used for matching tangential/lateral breas...

2016
Laurence Autret Julien Bert Yannick Lemaréchal Laurent Desbat Dimitris Visvikis

The verification of the dose delivered to a patient during radiation therapy is a particularly important step for ensuring treatment quality. This step, known as in vivo dosimetry can be realized using a bidimensional dosimeter named Electronic Portal Imaging Device (EPID). However, few methods enable the determination of an accurate and fully personalized 3D dose distribution for the most curr...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید