نتایج جستجو برای: failure plane angle

تعداد نتایج: 602398  

Journal: :Physical review letters 2016
A Korobenko V Milner

We use an optical centrifuge to align asymmetric top SO_{2} molecules by adiabatically spinning their most polarizable O-O axis. The effective centrifugal potential in the rotating frame confines the sulfur atoms to the plane of the laser-induced rotation, leading to the planar molecular alignment that persists after the molecules are released from the centrifuge. The periodic appearance of the...

Journal: :Journal of vision 2010
Chia-Ching Wu Chien-Chung Chen

To clarify the role of lateral interaction and uncertainty reduction in collinear flanker facilitation of contrast discrimination, we investigated the effect of flankers and spatial cueing on the contrast discrimination threshold. The task of the observers was to detect a 1.3 cyc/deg vertical Gabor target superimposed on one of the Gabor pedestals presented at 3 degrees to the left and right of...

Journal: :Vision Research 1998
J Hohnsbein S Mateeff

We studied the ability of human observers to detect abrupt changes in velocity of motion of a random dot pattern. The pattern moved horizontally for 0.9 s at velocity V0, then changed to V1 either in speed, or in direction for a time T and returned to the initial motion. The threshold duration for detection of the change was measured for initial speeds of 2, 4, 8 and 16 deg/s. The time to detec...

Journal: :Vision research 1993
E Castet J Lorenceau M Shiffrar C Bonnet

In this study, the perceived speed of a tilted line translating horizontally (for a duration of 167 msec) is evaluated with respect to a vertical line undergoing the same translation. Perceived speed of the oblique line is shown to be underestimated when compared to the vertical line. This bias increases: (1) when the line is further tilted, (2) with greater line lengths, (3) with lower contras...

Journal: :Vision Research 2005
Dimitar Mitov Tsvetalin Totev

Reaction time (RT) for detection of gratings of different spatial frequencies (SF, 0.87-13.87 c/d) and contrast (2-32 times above the detection threshold) was measured. It was found that at low stimulus contrast, 2 and 4 times above the detection threshold, the dependence of mean RT on SF is an "S"-type function with the two plateaus 50-60 ms apart. The standard deviation (SD) increases signifi...

Journal: :The Astrophysical journal 2000
Kraft Forman Jones Kenter Murray Aldcroft Elvis Evans Fabbiano Isobe Jerius Karovska Kim Prestwich Primini Schwartz Schreier Vikhlinin

We present first results from a Chandra X-Ray Observatory observation of the radio galaxy Centaurus A with the High-Resolution Camera. All previously reported major sources of X-ray emission including the bright nucleus, the jet, individual point sources, and diffuse emission are resolved or detected. The spatial resolution of this observation is better than 1&arcsec; in the center of the field...

Journal: :Visual neuroscience 2004
Patrick Monnier Steven K Shevell

Intense scrutiny has been focused on whether chromatic stimuli contribute to motion perception. The present study considers a related but different question: how does motion affect chromatic detection? Detection thresholds were measured for a disk that underwent a brief (13.3 ms) chromatic change in the L/(L+M) chromatic direction. The disk's presentation sequence and speed (0-16 deg/s) were ma...

2015
JAUME LLIBRE

We study the Liouvillian first integrals for the generalized Liénard polynomial differential systems of the form x′ = y, y′ = −g(x) − f(x)y, where g(x) and f(x) are arbitrary polynomials such that 2 ≤ deg g ≤ deg f .

2004
Joseph H. Silverman

Ailon and Rudnick have shown that if a, b ∈ C[T ] are multiplicatively independent polynomials, then deg (

Journal: :Journal of biomechanical engineering 2011
Michelle Roland M L Hull S M Howell

In a previous paper, we reported the virtual axis finder, which is a new method for finding the rotational axes of the knee. The virtual axis finder was validated through simulations that were subject to limitations. Hence, the objective of the present study was to perform a mechanical validation with two measurement modalities: 3D video-based motion analysis and marker-based roentgen stereopho...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید