Journal: :Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine 2000
Y C Cheung K N Yu R T Ho C P Yu

The accuracy of the dose planning system (Leksell GammaPlan) used in Gamma Knife (model-B) radiosurgery was verified using both the GafChromic films MD-55 (improved) and the EGS4 Monte Carlo technique. The Monte Carlo technique was employed to calculate the dose distribution along the x-, y- and z-axes when a single shot with opening of all 201 sources was delivered at the centre of a simulated...

Journal: :Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics 2010
Hani Alnawaf Martin J Butson Tsang Cheung Peter K N Yu

Gafchromic XRQA radiochromic film, is an effective tool for quality assurance and dose assessment in kilovoltage radiotherapy and diagnostic applications. Like other Gafchromic film products, XRQA film exhibits a variation in dose to reflected optical density response with angle of rotation when analysed with a light source that is partially or fully polarised such as a desktop scanner. Althoug...

Journal: :Medical physics 2006
Tsang Cheung Martin J Butson Peter K N Yu

High energy x-ray beam penumbra are measured using Gafchromic EBT film. Gafchromic EBT, due to its limited energy dependence and high spatial resolution provide a high level of accuracy for dose assessment in penumbral regions. The spatial resolution of film detector systems is normally limited by the scanning resolution of the densitometer. Penumbral widths (80%/20%) measured at Dmax were foun...

2014
Mishra Subhalaxmi T. Palani Selvam

Relative absorbed dose energy response correction, R, for various radiochromic films in water phantom is calculated by the use of the Monte Carlo-based EGSnrc code system for high energy brachytherapy sources 60Co, 137Cs, 192Ir and 169Yb. The corrections are calculated along the transverse axis of the sources (1-15 cm). The radiochromic films investigated are EBT, EBT2 (lot 020609 and lot 03110...

Hojatollah Shahbazian Jafar Fatahiasl Mansour Zabihzadeh Mohammad Ali Behrooz Mohammad Javad Tahmasebibirgani Nahid Chegeni Reza Maskani

Introduction: Photon contamination is a restriction on treatment with electron that increase dose to healthy tissue below the tumor. The aim of this study is to reduce the photon contamination using a magnet system. Materials and Methods: A mini-applicator equipped with two neodymium boron permanent magnets was designed which make it possible to adjust the d...

2014
Volker Rudat Alaa Nour Abdul Aziz Alaradi Adel Mohamed Saleh Altuwaijri

PURPOSE The purpose of this study was to compare the surface dose of 7-field IMRT (7 F-IMRT), tangential beam IMRT (TB-IMRT), and tangential beam 3D-CRT (3D-CRT) of breast cancer patients receiving adjuvant radiotherapy by means of in vivo GafChromic film dosimetry. MATERIAL AND METHODS Breast cancer patients receiving adjuvant radiotherapy of the whole breast or the chest wall were eligible ...

Journal: :Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine 2005
Tsang Cheung Martin J Butson Peter K N Yu

The absorption spectra of the GAFCHROMIC XR type R radiochromic film measured with reflectance spectroscopy have been investigated in order to analyze the dosimetry characteristics of the film. Like the XR type T film, this film features two peaks in its absorption spectrum, approximately at 676 and 618 nm, whose intensities increase with increasing absorbed dose. When the main absorption peak ...

حمید امامی شهرام منادی فریدون عباسی دوانی, محمد لامعی رشتی میترا انصاری

در پرتودرمانی، میزان دز داده شده به بافت هدف باید صحت بالایی داشته باشد، و عدم دقت در آن می‎تواند روی نتیجه‌­ی درمان اثر بگذارد. با پیدایش فیلم‎های جدید رادیوکرومیک، دزیمتری با فیلم به ابزاری قدرتمند برای تأیید و تضمین کیفیت پرتودرمانی بدل شده‎ است. فیلم‎های گاف‎کرومیک EBT2 به دلیل داشتن ویژگی‌­هایی مانند محدوده­‌ی حساسیت گسترده، قدرت تفکیک مکانی بالا و شرایط بازخوانی و حمل آسان، از جدیدترین و ...

Journal: :iranian journal of radiation research 0
i. setilo medical physics department, faculty of health sciences, university of the free state, bloemfontein 9300, south africa f.c.p. du plessis medical physics department, faculty of health sciences, university of the free state, bloemfontein 9300, south africa

background:  radiochromic film is used for radiation dose measurement, xr-rv3 is used in fluoroscopy and ebt2 film in radiation therapy. the aim was to determine if the dosimetric properties of these two films are comparable in megavolt photon beams. materials and methods: comparison measurements included: calibration curves, heterogeneous phantom dose profiles, and nasopharynx dose distributio...