نتایج جستجو برای: gafchromic xrct

تعداد نتایج: 399  

Journal: :Physics in medicine and biology 2002
Martin J Butson Tsang Cheung Peter K N Yu Peter Metcalfe

Variations in skin dose caused by a silicon-based burn dressing used in radiotherapy during treatment have been investigated. Measurement of these variations in skin dose has been achieved using thermoluminescent dosimeters (TLDs) and Gafchromic film. For a 6 MV x-ray beam results have shown that an approximately 0.4 mm thick silicon mesh dressing increases the average surface dose by approxima...

2016
Grzegorz Zwierzchowski Grzegorz Bielęda Janusz Skowronek Magdalena Mazur

PURPOSE Well-known defect of TG-43 based algorithms used in brachytherapy is a lack of information about interaction cross-sections, which are determined not only by electron density but also by atomic number. TG-186 recommendations with using of MBDCA (model-based dose calculation algorithm), accurate tissues segmentation, and the structure's elemental composition continue to create difficulti...

Journal: :Dento maxillo facial radiology 2013
A Al-Okshi M Nilsson A Petersson M Wiese C Lindh

OBJECTIVES To demonstrate the feasibility of GafChromic(®) XR-QA2 (ISP Corp., Wayne, NJ) as a dosemeter when performing measurements of the effective dose from three cone beam CT (CBCT) units and to compare the doses from examinations of three common dental clinical situations. A second aim was to compare the radiation doses for three digital panoramic units with the doses for the CBCT units. ...

Journal: :Physics in medicine and biology 2002
Tsang Cheung Martin J Butson Peter K N Yu

Assessment of skin dose delivered to patients from radiotherapy x-ray beams should be performed both inside and outside the prescribed treatment fields. A multilayer Gafchromic film detector which has high sensitivity for detection of radiation can be used to measure skin dose in a two-dimensional map over the skin surface if required. This is an advantage over other detectors, which only provi...

Journal: :Australasian Physics & Engineering Sciences in Medicine 2009

Journal: :Physics in medicine and biology 1998
A Ertl M Zehetmayer A Schöggl K Kitz R Koschuch H Stadtmann P Kindl

The aim of this study was to determine the shuttle dose for all collimator helmets (4, 8, 14 and 18 mm) of the Gamma Knife, model B, in Vienna, Austria. The additional dose accumulated during the transport of the patient in and out of the treatment position should be considered in the dose planning procedure of multicentre treatment regimens and in fractionated stereotactic Gamma Knife radiothe...

Journal: :Physics in medicine and biology 2002
Martin J Butson Peter K N Yu Tsang Cheung Peter Metcalfe

This short note investigates the dose characteristics of a relatively new high sensitivity radiochromic film (Gafchromic HS) and compares dose and energy response to various Gafchromic film types and radiographic (EDR-2) film. The original MD-55-1 and two improved sensitivity films, MD-55-2 and HS film, were investigated for energy and dose response. Results show that the energy response of the...

Journal: :Physics in medicine and biology 2003
Martin J Butson Peter K N Yu Tsang Cheung

Multi-leaf penumbral doses have been investigated for 6 MV x-rays and a Varian millennium multi-leaf collimator (MLC) using Gafchromic MD-55-2, radiochromic film and X-omat V radiographic film. An advantage of Gafchromic film for multi-leaf penumbral dose measurement is the relatively low energy dependence of the film. A comparison of penumbral dose measurements has also ascertained the effects...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید